Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2360702.1
Update Date:2018-02-20
Keywords:

Solution Type  Problem Resolution Sure

Solution  2360702.1 :   Cisco 93108 switch is getting Error Disabled on the Uplink Switch  


Related Items
  • Exadata X7-2 Hardware
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Sun Network Ethernet Switches
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-16782861731>

Applies to:

Exadata X7-2 Hardware - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Cisco switch 93108 uplink connection to Cisco N2K FEX getting disabled.

 

N2K %ETHPORT-5-IF_DOWN_ERROR_DISABLED: Interface Ethernet123/1/28 is down (Error disabled. Reason:BPDUGuard)

Changes

 

Cause

The Nexus 2K is a FEX and should only be connected to hosts and not switches.  The FEX can not disable bpdu guard by design and will disable a port if it receives an STP BPDU.

 

Solution

Connect the Oracle provided 93108 Management switch directly to the customer N5K.
 