![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2360702.1 : Cisco 93108 switch is getting Error Disabled on the Uplink Switch
In this Document
Created from <SR 3-16782861731> Applies to:Exadata X7-2 Hardware - Version All Versions and laterInformation in this document applies to any platform. SymptomsCisco switch 93108 uplink connection to Cisco N2K FEX getting disabled.
N2K %ETHPORT-5-IF_DOWN_ERROR_DISABLED: Interface Ethernet123/1/28 is down (Error disabled. Reason:BPDUGuard) Changes
CauseThe Nexus 2K is a FEX and should only be connected to hosts and not switches. The FEX can not disable bpdu guard by design and will disable a port if it receives an STP BPDU. SolutionConnect the Oracle provided 93108 Management switch directly to the customer N5K. Attachments This solution has no attachment |
||||||||||||||||||
|