Solution Type  Problem Resolution Sure

Solution  2359140.1 :   Diameter Signaling Router (DSR) - Measurement Data From Standby MP Blade Are Not Reported in Connection Performance Report  


Related Items
  • Oracle Communications Diameter Signaling Router (DSR)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec DSR
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-15570221191>

Applies to:

Oracle Communications Diameter Signaling Router (DSR) - Version DSR 7.0.1 and later
Tekelec

Symptoms

Measurement data from standby MP (Message Processor) blade are not reported in Connection Performance Report

 

Cause

Measurement data from the standby MP blade is not  reported in Connection Performance Report because dsr process does not runs on the standby MP.

 

Solution

It is expected and correct behavior that the measurement data from standby MP is not reported in connection performance report or any report that requires diameter related data.