Solution Type Problem Resolution Sure Solution 2359140.1 : Diameter Signaling Router (DSR) - Measurement Data From Standby MP Blade Are Not Reported in Connection Performance Report
In this Document
Created from <SR 3-15570221191> Applies to:Oracle Communications Diameter Signaling Router (DSR) - Version DSR 7.0.1 and laterTekelec SymptomsMeasurement data from standby MP (Message Processor) blade are not reported in Connection Performance Report
CauseMeasurement data from the standby MP blade is not reported in Connection Performance Report because dsr process does not runs on the standby MP.