Solution  2358558.1 :   T10000B - During Write ERP, The Hardware Declared SUCCESS But Tape Position Was Not As Expected, FSC: 3978, 3965  


Related Items
  • Sun StorageTek T10000B Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Changes
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for service personnel
Created from <SR 3-16802182547>

Applies to:

Sun StorageTek T10000B Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

During Write ERP, The Hardware Declared SUCCESS But Tape Position Was Not As Expected, FSC 3978 

FSC: 3965 RO_FSC_WRT_DISCONTINUITY_ERROR

FSC Encountered: 3961   Volser: 100257

Changes

 

Cause

FSC: 3965 RO_FSC_WRT_DISCONTINUITY_ERROR
MIM Code: NONE
FRU: MEDIA       CONF: 50%
FRU: HARDWARE   CONF: 50%
Summary: |OLD DATA NOT    |OVERWRITTEN ON  |WRITE           |
Field Text:
The drive was not able to successfully overwrite old data when ramping up to write.

Support Annotations:
T10000A/B - These errors can occur for one of two reasons:
1) the tape drive head is worn out - Run a health check and check for sliding diversity (SD) errors in the drive conditions tab.
2) the drive is getting servo offtrack errors. These typically occur on new tapes and can be worse on new drives. We have a code change for this problem. The code version is 1.48.105 for T10000A and 1.48.205 for T10000B drives. If the code needs to be upgraded contact t2 to schedule this activity with the customer.