Asset ID: |
1-72-2358558.1 |
Update Date: | 2018-02-13 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2358558.1
:
T10000B - During Write ERP, The Hardware Declared SUCCESS But Tape Position Was Not As Expected, FSC: 3978, 3965
Related Items |
- Sun StorageTek T10000B Tape Drive
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for service personnel
Created from <SR 3-16802182547>
Applies to:
Sun StorageTek T10000B Tape Drive - Version All Versions and later
Information in this document applies to any platform.
Symptoms
During Write ERP, The Hardware Declared SUCCESS But Tape Position Was Not As Expected, FSC 3978
FSC: 3965 RO_FSC_WRT_DISCONTINUITY_ERROR
FSC Encountered: 3961 Volser: 100257
Changes
Cause
FSC: 3965 RO_FSC_WRT_DISCONTINUITY_ERROR
MIM Code: NONE
FRU: MEDIA CONF: 50%
FRU: HARDWARE CONF: 50%
Summary: |OLD DATA NOT |OVERWRITTEN ON |WRITE |
Field Text:
The drive was not able to successfully overwrite old data when ramping up to write.
Support Annotations:
T10000A/B - These errors can occur for one of two reasons:
1) the tape drive head is worn out - Run a health check and check for sliding diversity (SD) errors in the drive conditions tab.
2) the drive is getting servo offtrack errors. These typically occur on new tapes and can be worse on new drives. We have a code change for this problem. The code version is 1.48.105 for T10000A and 1.48.205 for T10000B drives. If the code needs to be upgraded contact t2 to schedule this activity with the customer.
Solution
Attachments
This solution has no attachment