Solution Type  Problem Resolution Sure

Solution  2357448.1 :   Oracle ZFS Storage Appliance: ZS3-2 - 32GB DIMM PN: 7053841 Reported as PN: 7049085  


Related Items
  • Oracle ZFS Storage ZS3-2
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: ZS
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Contains information not shared with end customers.
Created from <SR 3-16664285486>

Applies to:

Oracle ZFS Storage ZS3-2 - Version All Versions to All Versions [Release All Releases]
7000 Appliance OS (Fishworks)

Symptoms

DIMMs in a ZS3-2 are reported as part number 7049085, however, that part number is only valid in a SPARC M5-32, M6-32 or Oracle SuperCluster M6-32. This problem was seen when attempting to determine the correct replacement part for a faulted DIMM in a ZFS Storage ZS3-2.

 

Changes

 

 

Cause

Some Hynix Semiconductor Inc. HMT84GR7AMR4A-H9 DIMMs were programmed with part number 7049085 but labeled as part number 7053841.

The Hynix Semiconductor Inc. HMT84GR7AMR4A-H9 DIMMs are used in both Oracle parts 7053841 and 7049085.

Oracle part number 7049085 is not a substitute for 7053841 because 7049085 includes some DIMM parts not qualified in a ZS3-2.

 7053841 possible DIMM parts:

  • Hynix HMT84GR7AMR4A-H9
  • Samsung M393B4G70DM0-YH9 

7049085 possible DIMM parts:

  • Hynix HMT84GR7AMR4A-H9
  • Hynix HMT84GR7MMR4A-H9
  • Samsung M393B4G70DM0-YH9
  • Samsung M393B4G70BM0-YH9

 

Solution

Replace a 32GB DIMM in a ZFS Storage ZS3-2 reported as part number 7049085 with part number 7053841.

 
Oracle ZFS Storage Appliance Customer Service Manual, Replacing a ZS3-2 DIMM

How to Replace a Memory DIMM in a Oracle ZFS Storage ZS3-2 [VCAP](Doc ID 1946369.1)

How to Replace a Memory DIMM on a Sun Netra X3-2 and a ZFS Storage ZS3-2 (Netra x4270m3) [Video](Doc ID 1597863.1)

How to Replace a Sun ZFS Unified Storage Appliance Memory DIMM [VCAP](Doc ID 1408348.1)

 