Solution Type  Problem Resolution Sure

Solution  2357292.1 :   Major Platofrm Alarm : Device Error  


Related Items
  • Oracle Communications EAGLE (Hardware)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec OS ELAP LSMS
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-16729169658>

Applies to:

Oracle Communications EAGLE (Hardware) - Version LSMS 13.2 and later
Information in this document applies to any platform.

Symptoms

Alarm indicating the NAS is running out of disk space

Cause

The ResyncDB backup files are too big because the database is not being truncated.
 
The ResyncDB should have no more than 1M records.
 

Solution

Although files were deleted from the NAS, the alarm did not clear. The alarm on the LSMS was stuck in alarmMgr. It has to be cleared with
 . /etc/profile; /usr/bin/snmptrap -v 2c -c public localhost '' LSMS-NAS-MIB::volumeRepaired enterprises s 'volume_repaired'