Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2355637.1
Update Date:2018-02-26
Keywords:

Solution Type  Problem Resolution Sure

Solution  2355637.1 :   FS System: After Replacing IOM at Capacity DE2-24C System Shows RAID_EVENT_ENCLOSURE_SBB_MIDPLANE_INTERCONNECT_STATUS_CRITICAL Events  


Related Items
  • Oracle FS1-2 Flash Storage System
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>Flash Storage>SN-EStor: FSx
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-16691903791>

Applies to:

Oracle FS1-2 Flash Storage System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

 A System Alert of RAID_EVENT_ENCLOSURE_SBB_MIDPLANE_INTERCONNECT_STATUS_CRITICAL is observed.

Changes

 An Input/Output Module (IOM) has recently been replaced in a DE2-24C Enclosure or a new DE2-24C Enclosure has been added to the system.

Cause

 IOMs from logistics and those in DE2-24C add-ons come with a firmware version (0010) that does not properly handle certain I2C inquiries in a timely fashion.

Solution

Upgrade the IOM firmware version to 001E. Since this version has been included with every Generally Available software releases with the FS1-2, the IOM upgrade will happen with a simple restart of the system. 

NOTE: a restart of the system will make the data on the FS1-2 inaccessible until the system is back up.

From the Oracle FS System Manager (GUI):

  1. Login in using the administrator account.
  2. Select Oracle FS from the menu bar.
  3. Select Restart
  4. Select OK in the pop-up window.

From the Oracle FS Command Line Interface (fscli):

  1. Log in using the administrator account.
  2. Issue the restart command:
    # fscli system -restart

    Command Succeeded

    #

References

<BUG:27439986> - ADD SUPPORT FOR ON-THE-FLY IOM UPDATE FOR DE ADD AND IOM GM IN R6
<BUG:27019515> - RAID_EVENT_ENCLOSURE_SBB_MIDPLANE_INTERCONNECT_STATUS_CRITICAL EVENTS
<BUG:19069260> - SMP OPERATION FAILED (ERROR_HW_TIMEOUT) IN PMCS LOGS; I2C.*FAILED FAULT DETECTED