Asset ID: |
1-72-2355213.1 |
Update Date: | 2018-02-14 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2355213.1
:
T7-2 System not booting. Timeout Waiting for SP reset to Clear
Related Categories |
- PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T7
|
In this Document
Applies to:
SPARC T7-2 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Symptoms
Before Hypervisor transitions to OBP, System may hang with message, NOTICE: Waiting to send a message to the SP
From event log:
21 Tue Nov 28 07:26:04 2017 System Log major
FPGA initialization failed. Running in degraded mode.
20 Tue Nov 28 07:22:42 2017 System Log critical
Failed to read FPGA address 0x2d19020 with status -1
19 Tue Nov 28 06:58:43 2017 System Log minor
Host: Powered On
From console log:
2017-11-28 05:57:40.804 0:0:0:0>IOH PCIe Configuration Space Register Test
2017-11-28 05:57:41.951 0:0:0:0>IOH PCIe Memory Space Register Test
2017-11-28 05:57:44.022 0:0:0:0>Setup Tunables
2017-11-28 05:57:44.162 0:0:0:0>HB PCIE LINK ENABLE
2017-11-28 05:58:35.199 0:0:0:0>WARNING: Timeout waiting for SP reset to clear
2017-11-28 06:00:06.930 0:0:0:0>WARNING: Timeout waiting for SP reset to clear
2017-11-28 06:00:58.148 0:0:0:0>WARNING: Timeout waiting for SP reset to clear
2017-11-28 06:01:49.366 0:0:0:0>WARNING: Timeout waiting for SP reset to clear
2017-11-28 06:01:50.131 0:0:0:0>ERROR:
ereport.chassis.post.io.test-fail@/SYS/MB/IOH0/IOS4/RP0/PCIE_LINK
reporting PCPU ID=0
TestTitle=HB PCIE LINK ENABLE
Operation=Check PCIE link trained (DLL Active)
END_ERROR
2017-11-28 06:02:06.947 0:0:0:0>FDD Message to GM timed out
.
2017-11-28 06:12:04.278 0:0:0:0>Setup LE TSB Page
2017-11-28 06:12:04.361 0:0:0:0>CHECK PCI TOPOLOGY
2017-11-28 06:12:04.416 0:0:0:0> NAC VID DID Width Speed Status
2017-11-28 06:12:04.436 0:0:0:0>--------------------------------------------------------------------------------
2017-11-28 06:12:04.456 0:0:0:0> /SYS/MB/IOH0/IOS0/RP0/PCIE_LINK 108e b008 8 G3 Clean
2017-11-28 06:12:04.477 0:0:0:0> /SYS/MB/SASHBA0 1000 0097 8 G3 Clean
2017-11-28 06:12:04.497 0:0:0:0> /SYS/MB/IOH0/IOS0/RP1/PCIE_LINK 108e b008 0 G0 Clean
2017-11-28 06:12:04.519 0:0:0:0> /SYS/MB/PCIE4 ------------------------------
2017-11-28 06:12:04.539 0:0:0:0> /SYS/MB/IOH0/IOS1/RP0/PCIE_LINK 108e b008 8 G2 Clean
2017-11-28 06:12:04.560 0:0:0:0> /SYS/MB/NET0 8086 1528 8 G2 Clean
2017-11-28 06:12:04.581 0:0:0:0> /SYS/MB/NET1 8086 1528 8 G2 Clean
2017-11-28 06:12:04.602 0:0:0:0> /SYS/MB/IOH0/IOS1/RP1/PCIE_LINK 108e b008 0 G0 Clean
2017-11-28 06:12:04.622 0:0:0:0> /SYS/MB/PCIE3 ------------------------------
2017-11-28 06:12:04.643 0:0:0:0> /SYS/MB/IOH0/IOS2/RP0/PCIE_LINK 108e b008 4 G3 Clean
2017-11-28 06:12:04.664 0:0:0:0> /SYS/MB/PCIE2 1077 2031 4 G3 Clean
2017-11-28 06:12:04.685 0:0:0:0> /SYS/MB/PCIE2 1077 2031 4 G3 Clean
2017-11-28 06:12:04.706 0:0:0:0> /SYS/MB/IOH0/IOS3/RP0/PCIE_LINK 108e b008 0 G0 Clean
2017-11-28 06:12:04.727 0:0:0:0> /SYS/MB/PCIE1 ------------------------------
2017-11-28 06:12:04.747 0:0:0:0> /SYS/MB/IOH0/IOS4/RP0/PCIE_LINK -----------ERRORS!------------ *******
2017-11-28 06:12:04.768 0:0:0:0> /SYS/MB/SPM ------------------------------
2017-11-28 06:12:04.788 0:0:0:0> /SYS/MB/IOH1/IOS0/RP0/PCIE_LINK 108e b008 8 G3 Clean
2017-11-28 06:12:04.809 0:0:0:0> /SYS/MB/SASHBA1 1000 0097 8 G3 Clean
2017-11-28 06:12:04.830 0:0:0:0> /SYS/MB/IOH1/IOS0/RP1/PCIE_LINK 108e b008 4 G3 Clean
2017-11-28 06:12:04.851 0:0:0:0> /SYS/MB/PCIE6 1077 2031 4 G3 Clean
2017-11-28 06:12:04.872 0:0:0:0> /SYS/MB/PCIE6 1077 2031 4 G3 Clean
2017-11-28 06:12:04.893 0:0:0:0> /SYS/MB/IOH1/IOS1/RP0/PCIE_LINK 108e b008 0 G0 Clean
2017-11-28 06:12:04.914 0:0:0:0> /SYS/MB/PCIE8 ------------------------------
2017-11-28 06:12:04.934 0:0:0:0> /SYS/MB/IOH1/IOS2/RP0/PCIE_LINK 108e b008 0 G0 Clean
2017-11-28 06:12:04.955 0:0:0:0> /SYS/MB/PCIE7 ------------------------------
2017-11-28 06:12:04.975 0:0:0:0> /SYS/MB/IOH1/IOS3/RP0/PCIE_LINK 108e b008 8 G2 Clean
2017-11-28 06:12:04.996 0:0:0:0> /SYS/MB/NET2 8086 1528 8 G2 Clean
2017-11-28 06:12:05.017 0:0:0:0> /SYS/MB/NET3 8086 1528 8 G2 Clean
2017-11-28 06:12:05.038 0:0:0:0> /SYS/MB/IOH1/IOS3/RP1/PCIE_LINK 108e b008 0 G0 Clean
2017-11-28 06:12:05.059 0:0:0:0> /SYS/MB/PCIE5 ------------------------------
2017-11-28 06:12:05.079 0:0:0:0> /SYS/MB/IOH1/IOS4/RP0/PCIE_LINK 108e b008 1 G2 Clean
2017-11-28 06:12:05.100 0:0:0:0> /SYS/MB/USB_CTRL 104c 8241 1 G2 Clean
2017-11-28 06:12:05.135 0:0:0:0>Disable IOH Link Errors
ILOM/Traces/CRIT.log
OTHER CRITICAL 2017-11-28 05:57:55.840166 1693 fpga_plat_emx.c:776 fpga_data_get8(0x2d13001) = 0x00, err=-1
OTHER CRITICAL 2017-11-28 05:57:59.250237 2106 fpga_plat_emx.c:530 fpga_data_put8(0x2d19128) <= 0xc6, err=-1
libfpga_plat.so.1(fpga_data_put8+0x168) [0xb6630fc4]
libfpga_plat.so.1(fpga_put8+0x18) [0xb6631018]
libhalcommon.so.1(hc_fpga_reenable_system_irq+0x44) [0xb6851348]
pod(host_sys_irq_cb+0x5d4) [0x66f48]
pod(pod_gpioint_testfds+0x17c) [0x675b0]
pod() [0x6796c]
OTHER CRITICAL 2017-11-28 05:58:08.330221 1954 fpga_plat_emx.c:776 fpga_data_get8(0x2d30000) = 0xb5, err=-1
OTHER CRITICAL 2017-11-28 05:58:18.910259 2107 fpga_plat_emx.c:776 fpga_data_get8(0x2d13580) = 0x00, err=-1
OTHER CRITICAL 2017-11-28 05:58:29.180101 1693 fpga_plat_emx.c:776 fpga_data_get8(0x2d13081) = 0x00, err=-1
OTHER CRITICAL 2017-11-28 05:58:32.490141 2106 fpga_plat_emx.c:776 fpga_data_get8(0x2d19022) = 0x00, err=-1
OTHER CRITICAL 2017-11-28 05:58:41.570206 1954 fpga_plat_emx.c:530 fpga_data_put8(0x2d30000) <= 0xff, err=-1
libfpga_plat.so.1(fpga_data_put8+0x168) [0xb677cfc4]
libfpga_plat.so.1(fpga_put8+0x18) [0xb677d018]
libhalcommon.so.1(hc_set_fpga_gm_status+0x2c)
SP messages:
Dec 11 15:45:07 SAT1OSPIF035 kernel: USER1 irq possibly not serviced.
Clearing it
Dec 11 15:45:10 SAT1OSPIF035 kernel: parity mismatch 0x0!=0x1 on read8
0x2d13580, data 0x2, lpc_down=1, reg0=0x82d13580, tries=5
Dec 11 15:45:10 SAT1OSPIF035 kernel: siocfg8 : 0x0
Dec 11 15:45:10 SAT1OSPIF035 kernel: siocfg3 : 0xa
Dec 11 15:45:10 SAT1OSPIF035 kernel: power good : 0x1
Dec 11 15:45:11 SAT1OSPIF035 kernel: sys_irq=0xff resending irq
Dec 11 15:45:11 SAT1OSPIF035 kernel: parity mismatch 0x0!=0x1 on read8
0x2d32000, data 0x2, lpc_down=1, reg0=0x2d32000, tries=5
Dec 11 15:45:11 SAT1OSPIF035 kernel: siocfg8 : 0x0
Dec 11 15:45:11 SAT1OSPIF035 kernel: siocfg3 : 0xa
Dec 11 15:45:11 SAT1OSPIF035 kernel: power good : 0x1
Dec 11 15:45:27 SAT1OSPIF035 kernel: sys_irq=0x0 resending irq
Dec 11 15:46:01 SAT1OSPIF035 last message repeated 2 times
Dec 11 15:46:35 SAT1OSPIF035 last message repeated 2 times
Dec 11 15:46:51 SAT1OSPIF035 kernel: USER1 irq possibly not serviced.
Clearing it
Dec 11 15:46:52 SAT1OSPIF035 kernel: parity mismatch 0x0!=0x1 on read8
0x2d13580, data 0x2, lpc_down=1, reg0=0x82d13580, tries=5
Dec 11 15:46:52 SAT1OSPIF035 kernel: siocfg8 : 0x0
Dec 11 15:46:52 SAT1OSPIF035 kernel: siocfg3 : 0xa
Dec 11 15:46:52 SAT1OSPIF035 kernel: power good : 0x1
Dec 11 15:46:55 SAT1OSPIF035 kernel: sys_irq=0xff resending irq
Cause
Communication between the T7-2 system SPM and the T7-2 FPGA over the LPC bus can hang with
the latest combinations of SPM and FPGA code. Reference Bug 27275276.
Solution
Update T7-2 MB FPGA to 11.3.3.3 (Patch 27353106: FIRMWARE: SPARC T7-2 SYSTEMS HW PROGRAMMABLES 1.0.15).
Please be advise, update is CLI only (load source....) and ACs power cycle system are required to completed the HW Programmables installation.
Attachments
This solution has no attachment