![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2355106.1 : IBM LTO7 - Drives are Showing a Port Speed of 1Gb
In this Document
Applies to:IBM LTO7 Tape Drive - Version All Versions and laterInformation in this document applies to any platform. SymptomsIBM LTO7 Drives are Showing a Port Speed of 1Gb. After upgrading the drives to G9Q2 code, the drives are reporting to the library an FC port speed of 1Gb even though the switch confirms the expected higher connection speeds. Changes
CauseThis issue is due to a change in the number of bytes in a field reported by the IBM drive and does not affect the drive's performance. SolutionSL3000/SL8500 released code that correctly reports the speed when using the newest IBM drive codes. This issue does not affect the ADI drive interface, only the LDI interface. The release of FRS-8.60 and FRS 4.50 library codes. Attachments This solution has no attachment |
||||||||||||||||||
|