![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2353672.1 : IBM LTO7 - Tape Drive Generates Short Tapes, Error Code 7420 in Drive Dump
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:IBM LTO7 Tape Drive - Version All Versions and laterInformation in this document applies to any platform. Microcode G9Q2 is the current version for an IBM LTO 7 drive. SymptomsLTO7 Tape Drive Generates short tapes - EOMs tapes prematurely at 1-2 TB or less written. Changes
Cause36 7420h FUJIFILM 7EXV0GMW G9Q2 (mf160923b) 7420h 01h 21 01 00 1b 32 bb 11 6c 22 15 6: Drive or Media 407412140 44d 07h:36m:49s A 49 7420: FsczzERRMAP_MED_DETECT_DEAD_HEAD_WRITE SolutionReplace the tape drive. Attachments This solution has no attachment |
||||||||||||||||||
|