Asset ID: |
1-72-2350736.1 |
Update Date: | 2018-01-24 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2350736.1
:
T10000D - Drive Communication Time-Out FSC 0932
Related Items |
- StorageTek T10000D Tape Drive
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for service personnel
Created from <SR 3-16662553985>
Applies to:
StorageTek T10000D Tape Drive - Version All Versions and later
Information in this document applies to any platform.
Symptoms
FSC 1320: Drive communication time-out From the library.
FSC = 0932 from the drive.
1116 - (3X) Drive is not online - checkState src, hliLsm=2
(Errors Started - 2018-01-09 18:07:42 Errors Stopped - 2018-01-09 18:11:54)
1320 - (3X) Drive communication time-out 1,3,2,1,2
(Errors Started - 2018-01-08 18:55:03 Errors Stopped - 2018-01-12 15:52:03)
3287 - (2X) Device transitioned to not ready, address=(Drive_Bay25)1,3,2,1,2
(Errors Started - 2018-01-08 19:04:04 Errors Stopped - 2018-01-09 18:13:18)
3955 - (8X) Error from device Code: 604 - Drive is not functional, drive 1,3,2,1,2: getState FAILED, resultCode = 6406
(Errors Started - 2018-01-09 18:08:09 Errors Stopped - 2018-01-12 15:57:03)
3993 - (2X) Device added, device=drive
(Errors Started - 2018-01-08 19:04:04 Errors Stopped - 2018-01-09 18:13:17)
5025 - (2X) FSC reported with announce drive reset FSC = 0932
(Errors Started - 2018-01-08 19:04:04 Errors Stopped - 2018-01-09 18:13:17)
Cause
FSC Dictionary Description:
MODEL = T10000D
FSC = 0932
(FSC Match Found in Rev. 4.13)
FSC: 0932 KER_FSC_LEVEL_13_DC_ADDRESS_ERROR
MIM Code: INOPERABLE
FRU: MICROCODE CONF: 80%
FRU: HARDWARE CONF: 20%
Summary: |INVALID UCODE |REGISTER VALUE | *** |
Field Text:
CCTU card received a level 13 interrupt. This indicates an internal Bus fault
Solution
Replaced the drive.
Attachments