Solution Type  Problem Resolution Sure

Solution  2350527.1 :   T10000B - Tape Drive Error Code 2623, Drive Offline  


Related Items
  • Sun StorageTek T10000B Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-16656902971>

Applies to:

Sun StorageTek T10000B Tape Drive - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

SSC - DMF T10000B, error code 2623, drive offline, job was restarted.

Tape drive was unloaded and reset but error remained.

Changes

 

Cause

Drive SNO FSC is 2623
(FSC Exact Match Found)
FSC: 2623 ASC_FSC_INV_CMD_ST_IN_SUCC_WRT
MIM Code: INOPERABLE

FRU: MICROCODE CONF: 100%

Summary: |INVALID UCODE |INVALID STATE | *** |

Field Text:
Microcode cannot determine what status was presented to the channel.
 

Solution

1. Need to inspect the drive physically for any component failure.   If there is any stuck tape, remove and reboot the drive.
2. Remove the drive from the bay and ensure that the cables are connected properly. If not, remove and repair cables, re-install and bring the drive online via SL Console.
3. If the issue still persists and drive does not power up, then replace the drive.
4. Make the drive online via SL Console.
5. Run diagnostics test and perform multiple moves to ensure that the drive mounts without any issues.
 


Attachments