Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2349810.1
Update Date:2018-02-07
Keywords:

Solution Type  Problem Resolution Sure

Solution  2349810.1 :   Could Not Connect To Local LPU Port 6683 (IO::Socket::INET: Connect: Connection Refused)  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec OS ELAP LSMS
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-16617852661>

Applies to:

Oracle Communications EAGLE (Software) - Version ELAP 10.1 and later
Information in this document applies to any platform.

Symptoms

Could not connect to local LPU port 6683 (IO::Socket::INET: connect: Connection refused) - error is generated when query ELAP for sub information

Cause

Software not running. No functionality, if software not running

Solution

Restart software. Also reboot the ELAPs if there has not been a clean reboot for some time