Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2349123.1
Update Date:2018-01-19
Keywords:

Solution Type  Problem Resolution Sure

Solution  2349123.1 :   SL48 - Error Lamp Blinking. Msg " Warning: Not Enough Slots Free for Movement!" in DumpAlltrace  


Related Items
  • Sun StorageTek SL48 Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: OEM Drive and Library
  •  


Error LED blinking.

In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-16565895628>

Applies to:

Sun StorageTek SL48 Tape Library - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

Error LED lit
Warning: Not Enough Slots Free for Movement

Changes

 None

Cause

Library is full.
Message
"Warning: Not enough slots free for movement!"
seen in DumpAllTrace.

Solution

Review library contents and free up space.

References

<NOTE:1484746.1> - SL24/SL48 - How to Obtain Error Code Logs

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.