Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2347752.1
Update Date:2018-01-11
Keywords:

Solution Type  Problem Resolution Sure

Solution  2347752.1 :   Sefos Crashing and dropping all connections on ES1-24 or 72P Switch  


Related Items
  • Sun Network Switch
  •  
  • Oracle Switch ES1-24
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Sun Network Ethernet Switches
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-14290080972>

Applies to:

Sun Network Switch - Version All Versions to All Versions [Release All Releases]
Oracle Switch ES1-24 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

All connections getting dropped over Sun Ethernet Switch.

Messages show the following:

 

  Dec 13 07:44:17 switch2logger: iss DIED  TOTAL_DEATHS:1 <---------------------------sefos restarted
  Dec 13 07:44:43 switch2kernel: focalpoint: Found VantagePoint at
  PCI Bus #02 Device ID 0xfde1 Revision 0x0101803d
  Dec 13 07:44:43 switch2kernel: focalpoint:
  ---------------------------------
  Dec 13 07:44:43 switch2kernel: focalpoint: VantagePoint 1.1, build
  #61
  Dec 13 07:44:43 switch2kernel: focalpoint:
  ---------------------------------
  Dec 13 07:44:43 switch2kernel: focalpoint: Found VantagePoint at
  PCI Bus #05 Device ID 0xfde1 Revision 0x0101803d
  Dec 13 07:44:43 switch2kernel: focalpoint:
  ---------------------------------
  Dec 13 07:44:43 switch2kernel: focalpoint: VantagePoint 1.1, build
  #61
  Dec 13 07:44:43 switch2kernel: focalpoint:
  ---------------------------------
  Dec 13 07:44:43 switch2logger: RESTART OUTPUT - -
  Dec 13 07:44:43 switch2logger: iss DIED  REASON: NO_PS

 
  .
  .
   /SYS/sefos
      Properties:
          type = Fabric Switch OS
          status = enabled
          uptime = 0 days, 18:02:56 <--------------------------------Restart Time
 

Changes

 New network monitoring application added to the Customer network can trigger this issue. End user running snmpget can also trigger this issue.

Cause

Firmware versions older than 1.3.1.21 (ES1-24), or 1.2.2.23 (72P) can hit this issue.

Solution

Disable ILOM SNMP as a work around or install firmware version 1.3.1.21 or later for ES1-24 or install 1.2.2.23 or later for 72P


Disable SNMP monitoring from the ILOM CLI prompt as a quick work around.
 
-> cd /SP/services/snmp
-> set servicestate=disabled


Download Patch 13255111: SUN NETWORK 10GBE SWITCH 72P 1.2 to get the latest version of firmware for the 72P and follow the patch README to update firmware
Download Patch 17050841: ORACLE SWITCH ES1-24 1.3 to get the latest version of firmware for the ES1-24  and follow the patch README to update firmware
 

 

 


 

References

<BUG:25569415> - SEFOS RESTART
<BUG:25071400> - RIP: SEFOS CRASH DURING CONFIGURATION
<BUG:21474511> - DOING SHUT/NO SHUT ON PORT-CHANNEL INTERFACES RESULTED IN A CRASH
<BUG:21609537> - INCONSISTENT PVRST BEHAVIOUR, ALSO CONSISTENTLY CRASHES