![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2347752.1 : Sefos Crashing and dropping all connections on ES1-24 or 72P Switch
In this Document
Created from <SR 3-14290080972> Applies to:Sun Network Switch - Version All Versions to All Versions [Release All Releases]Oracle Switch ES1-24 - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. SymptomsAll connections getting dropped over Sun Ethernet Switch. ChangesNew network monitoring application added to the Customer network can trigger this issue. End user running snmpget can also trigger this issue. CauseFirmware versions older than 1.3.1.21 (ES1-24), or 1.2.2.23 (72P) can hit this issue. SolutionDisable ILOM SNMP as a work around or install firmware version 1.3.1.21 or later for ES1-24 or install 1.2.2.23 or later for 72P
Download Patch 13255111: SUN NETWORK 10GBE SWITCH 72P 1.2 to get the latest version of firmware for the 72P and follow the patch README to update firmware
Download Patch 17050841: ORACLE SWITCH ES1-24 1.3 to get the latest version of firmware for the ES1-24 and follow the patch README to update firmware
References<BUG:25569415> - SEFOS RESTART<BUG:25071400> - RIP: SEFOS CRASH DURING CONFIGURATION <BUG:21474511> - DOING SHUT/NO SHUT ON PORT-CHANNEL INTERFACES RESULTED IN A CRASH <BUG:21609537> - INCONSISTENT PVRST BEHAVIOUR, ALSO CONSISTENTLY CRASHES Attachments This solution has no attachment |
||||||||||||||||||||
|