![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2347684.1 : Cannot Install Solaris 11.3 on new X7-2
WARNING: gfxp_fb_ioctl: Could not initialize console WARNING: terminal emulator : Compatible fb not found WARNING: consconfig: terminal emulator failed to initialize Booting 'Oracle Solaris 11.3.27.4.0' Loading cd0/platform/i86pc/kernel/amd64/unix: 0%...done. Loading cd0/platform/i86pc/amd64/boot_archive: 0%...5%...11%...17%...23%... 30%...36%...43%...49%...56%...62%...69%...75%...82%...88%...95%...done. In this Document
Created from <SR 3-16567237351> Applies to:Solaris x64/x86 Operating System - Version 11.3 to 11.3 [Release 11.0]Exadata X7-2 Hardware - Version All Versions and later x86 64 bit Attempts to install Oracle Solaris 11.3 on X7-2 might fail SymptomsUnable to boot a X7-2 system from DVD, network or USB using Oracle Solaris 11.3 SRU 23 (minimum). Loading cd0/platform/i86pc/kernel/amd64/unix: 0%...done.
Loading cd0/platform/i86pc/amd64/boot_archive: 0%.....95%...done. After this, the boot does not progress further.
WARNING: gfxp_fb_ioctl: Could not initialize console
WARNING: terminal emulator : Compatible fb not found WARNING: consconfig: terminal emulator failed to initialize CauseThis issue is described in X7-2 release notes in 'known Solaris issues' section : SolutionThe following workaround is available: While booting, modify grub2 menu and add this to the multiboot line: -B console=ttya,ttya-mode=\"115200,8,n,1,-\" For details about how to edit the multiboot see: x86: Adding Kernel Arguments by Editing the GRUB Menu at Boot Time https://docs.oracle.com/cd/E53394_01/html/E54742/glyas.html Permanent fix: At this time, only a Interim Diagnostic Relief (IDR) is available which must be requested from Oracle Support. References<BUG:27247860> - X7-2 GETTING "GFX_PRIVATE: WARNING GFXP_FB_IOCTL: COULD NOT INITIALIZE CONSOLE"<BUG:27347775> - CANNOT BOOT 11.3.27 WITH DVD ON X7-2 <BUG:27126273> - VGA TEXT CONSOLE CAN NOT USE BRIDGE_CTL VGA_ENABLE TO FIND CONSOLE FRAME BUFFER <BUG:25653304> - ENABLE VGA ON X7-2/L AND X7-8 Attachments This solution has no attachment |
||||||||||||||||||
|