SL150 library >>Error: Bridge drive Failure.

In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-16456944929>

Applies to:

StorageTek SL150 Modular Tape Library - Version All Versions to All Versions [Release All Releases]
LTO Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

 BRIDGE_DRIVE_FAILURE - Fault Code:9024
 It could be Repeated issue on same drive or a new problem in the library.

SL150 Fault Codes solution: for error code: 9024
faultString="BRIDGE_DRIVE_FAILURE"
helpString="Reseat/replace drive. Inspect/replace robot. Replace motherboard"

SL150 Library Code Dictionary : 9024 "Drive has no Power Supply"

Changes

Previous drive was replaced for same issue and now repeating again.

Cause

Cause could be one of the following :

  • The drive has lost Power or communication with Library.
  • Error: 3317 "Bad drive state for move"
  • Error: 6457 "The drive is reporting a drive error."

          A Reseat of the drive is needed.

Solution

1. Do library proper shutdown from Web GUI.
2. Interchange Drive from Module-1 top (issue creating drive / suspected drive) to Module-1 Bottom Drive. 
3. Re-seat the both power supply on the Base Module or on the module where drive is seated. <<--------- Because SL150 Library Code Dictionary : 9024 points to - "Drive has no Power Supply"
4. Re-seat the Robot Assembly in the Base Module.                                                            <<---------- Because SL150 Fault Codes solution for 9024 suspects Robot as well.
5. After above steps, Power ON library and waiting for 10 minutes to complete the Initialization and then check for the error.
6. If the Current library firmware at low level need to update to latest.
7. If the Current drive firmware at low level need to update to latest.

First upgrade Library firmware to latest via Library Web GUI                               ----->> Log into library GUI --- Firmware --- Library Firmware -- Click on Update ---- Browse and give the downloaded library firmware file path.
Second update drive firmware to latest one by one via same library Web GUI       ----->> Log into library GUI --- Firmware --- Drive Firmware -- Click on Update ---- Browse and give the downloaded Drive firmware file path.

By Following all above steps one by one in same sequence, Issue could be resolved.

The following referenced documents below will be help full.


 

References

<NOTE:1474172.1> - SL150 - How to Find Firmware Update Patches and Upgrade the StorageTek SL150 Modular Tape Library With Those Firmware Patches
<NOTE:1952297.1> - SL150 – How to Update the Tape Drive Firmware via WEB BUI
<NOTE:1587435.1> - SL150 - How To Change The Assignment of the Bridge Drive.

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback