Solution Type  Problem Resolution Sure

Solution  2342050.1 :   T10000A - DUMP FE01, Drive Not Available to Library  


Related Items
  • Sun StorageTek T10000A Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: Remote
  •  




In this Document
Symptoms
Cause
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: confidential for service personnel
Created from <SR 3-16424752901>

Applies to:

Sun StorageTek T10000A Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Tape Drive Bay 33 is not available to SL8500.
We tried reboot via SLConsole no success

Cause

Collected DUMP and in splat show FSC FE01:

Drive SNO FSC is fe01
(FSC Exact Match Found)
FSC: FE01 ITZ_FSC_DC_CMPR_DIAGNOSTIC_FAILED
MIM Code: INOPERABLE
FRU: HARDWARE CONF: 95%
FRU: MICROCODE CONF: 5%
Summary: |WAKEUP DIAG |FAILED |REGISTER VALUE |
Field Text:
The DC hardware compression wakeup diagnostic failed.
 

Solution

We replaced the tape drive according action plan.

SL8500 - How to Remove and Replace a Tape Drive in SL8500 Library (Doc ID 2180418.1)


 