![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2342050.1 : T10000A - DUMP FE01, Drive Not Available to Library
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:Sun StorageTek T10000A Tape Drive - Version All Versions and laterInformation in this document applies to any platform. SymptomsTape Drive Bay 33 is not available to SL8500. CauseCollected DUMP and in splat show FSC FE01: Drive SNO FSC is fe01 SolutionWe replaced the tape drive according action plan. SL8500 - How to Remove and Replace a Tape Drive in SL8500 Library (Doc ID 2180418.1)
References<BUG:15971124> - POSTBANK BONN DEAD DRIVES DUE TO SNO FE01 AND 613B<NOTE:1560073.1> - SL8500/SL3000 - Result Code 1320 - Troubleshooting Drive Communication Timeout Errors Attachments This solution has no attachment |
||||||||||||||||||
|