Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2340989.1
Update Date:2018-01-16
Keywords:

Solution Type  Problem Resolution Sure

Solution  2340989.1 :   DRBD Not Replicating On ELAP A  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec OS ELAP LSMS
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-16452316811>

Applies to:

Oracle Communications EAGLE (Software) - Version ELAP 9.0 and later
Information in this document applies to any platform.

Symptoms

"DRBD not replicating" alarm on EPAP A and on Eagle.

Cause

The alamMgr process has been hung since 12/8/2017
undetermined

Solution

Kill and restart alamMgr process. to clear Alarm.