Solution Type
Problem Resolution Sure
Solution
2340989.1
:
DRBD Not Replicating On ELAP A
Related Items |
- Oracle Communications EAGLE (Software)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec OS ELAP LSMS
|
In this Document
Created from <SR 3-16452316811>
Applies to:
Oracle Communications EAGLE (Software) - Version ELAP 9.0 and later
Information in this document applies to any platform.
Symptoms
"DRBD not replicating" alarm on EPAP A and on Eagle.
Cause
The alamMgr process has been hung since 12/8/2017
undetermined
Solution
Kill and restart alamMgr process. to clear Alarm.