Asset ID: |
1-72-2339807.1 |
Update Date: | 2017-12-18 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2339807.1
:
T10000 - Drive Requesting Too Many Cleanings, Result Code 6453
Related Items |
- Sun StorageTek T10000B Tape Drive
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
|
In this Document
Created from <SR 3-16408487398>
Applies to:
Sun StorageTek T10000B Tape Drive - Version All Versions and later
Information in this document applies to any platform.
Symptoms
Drive requesting too many cleans.
FSC 3961
Result Code 6453
694 2017-12-02T02:43:06.653 1.1.-2.1.3 root hli0 move 38588001 warn 3992 "Warning from device", Data=<response sequence="2049009" final="true"><command>rewindUnload</command><result identifier="1"><resultStatus><resultSeverity>warn</resultSeverity><resultCode>6434</resultCode><resultText><!|CDATA|drive 1,1,-2,1,3: rewindUnload Successful with mediaError: Cartridge Label: P09376T1, FSC: 3961||></resultText><operationalState>000</operationalState></resultStatus></result></response>
1748 2017-12-05T04:18:34.203 1.1.-2.1.3 root hli0 move 41088401 error 3955 "Error from device Code: 608 - Drive load failed due to expired clean cartridge", Data=<response sequence="2176676" final="true"><command>load</command><result identifier="1"><resultStatus><resultSeverity>error</resultSeverity><resultCode>6453</resultCode><resultText><!|CDATA|drive 1,1,-2,1,3: load Failed with unitCheck 5703, CartLabel = CLN356CL (driveType = T10000b-Enc, driveFirmware = 1.52.206-5.30, sn = 572004000306) FSC: 5703||></resultText><operationalState>608</operationalState></resultStatus><currentCleanUsage>52</currentCleanUsage><maxCleanUsage>51</maxCleanUsage><faultSymptomCode>5703</faultSymptomCode><STAPacketVersion>2</STAPacketVersion></result></response>
1749 2017-12-05T04:18:34.227 1.1.-2.1.3 root hli0 move 41088401 error 3336 "Drive detected an expired clean cartridge - load retry not allowed - on load", volumeLabel=CLN356CL hliLsm=0
1750 2017-12-05T04:18:34.345 1.1.-2.1.3 root hli0 move 41088401 warn 3992 "Warning from device", Data=<response sequence="2176680" final="true"><command>rewindUnload</command><result identifier="1"><resultStatus><resultSeverity>warn</resultSeverity><resultCode>6434</resultCode><resultText><!|CDATA|drive 1,1,-2,1,3: rewindUnload Successful with Expired Cleaning Cartridge (cartLabel = CLN356CL) FSC: 5703||></resultText><operationalState>000</operationalState></resultStatus></result></response>
1874 2017-12-12T00:55:24.569 1.1.-2.1.3 root hli0 move 46272201 error 3955 "Error from device Code: 608 - Drive load failed due to expired clean cartridge", Data=<response sequence="2458949" final="true"><command>load</command><result identifier="1"><resultStatus><resultSeverity>error</resultSeverity><resultCode>6453</resultCode><resultText><!|CDATA|drive 1,1,-2,1,3: load Failed with unitCheck 5703, CartLabel = CLN357CL (driveType = T10000b-Enc, driveFirmware = 1.52.206-5.30, sn = 572004000306) FSC: 5703||></resultText><operationalState>608</operationalState></resultStatus><currentCleanUsage>52</currentCleanUsage><maxCleanUsage>51</maxCleanUsage><faultSymptomCode>5703</faultSymptomCode><STAPacketVersion>2</STAPacketVersion></result></response>
1875 2017-12-12T00:55:24.592 1.1.-2.1.3 root hli0 move 46272201 error 3336 "Drive detected an expired clean cartridge - load retry not allowed - on load", volumeLabel=CLN357CL hliLsm=0
1876 2017-12-12T00:55:24.707 1.1.-2.1.3 root hli0 move 46272201 warn 3992 "Warning from device", Data=<response sequence="2458950" final="true"><command>rewindUnload</command><result identifier="1"><resultStatus><resultSeverity>warn</resultSeverity><resultCode>6434</resultCode><resultText><!|CDATA|drive 1,1,-2,1,3: rewindUnload Successful with Expired Cleaning Cartridge (cartLabel = CLN357CL) FSC: 5703||></resultText><operationalState>000</operationalState></resultStatus></result></response>
1878 2017-12-12T01:20:21.160 1.1.-2.1.3 root hli0 move 46280801 warn 3992 "Warning from device", Data=<response sequence="2459530" final="true"><command>rewindUnload</command><result identifier="1"><resultStatus><resultSeverity>warn</resultSeverity><resultCode>6434</resultCode><resultText><!|CDATA|drive 1,1,-2,1,3: rewindUnload Successful with unitCheck 395B (cartLabel = P02171T1)||></resultText><operationalState>000</operationalState></resultStatus></result></response>
1880 2017-12-12T01:35:23.787 1.1.-2.1.3 root hli0 move 46285701 warn 3992 "Warning from device", Data=<response sequence="2459860" final="true"><command>rewindUnload</command><r
Cause
Expired cleaning cartridge.
Solution
Cleaning cartridges are expired and need to be replaced.
Acquire good cleaning cartridges, clean the drive and run drive diagnostics.
Attachments
This solution has no attachment