Symptoms

Drive requesting too many cleans.

FSC 3961

Result Code 6453

 694 2017-12-02T02:43:06.653 1.1.-2.1.3 root hli0 move 38588001 warn 3992 "Warning from device", Data=<response sequence="2049009" final="true"><command>rewindUnload</command><result identifier="1"><resultStatus><resultSeverity>warn</resultSeverity><resultCode>6434</resultCode><resultText><!|CDATA|drive 1,1,-2,1,3: rewindUnload Successful with mediaError: Cartridge Label: P09376T1, FSC: 3961||></resultText><operationalState>000</operationalState></resultStatus></result></response>
1748 2017-12-05T04:18:34.203 1.1.-2.1.3 root hli0 move 41088401 error 3955 "Error from device Code: 608 - Drive load failed due to expired clean cartridge", Data=<response sequence="2176676" final="true"><command>load</command><result identifier="1"><resultStatus><resultSeverity>error</resultSeverity><resultCode>6453</resultCode><resultText><!|CDATA|drive 1,1,-2,1,3: load Failed with unitCheck 5703, CartLabel = CLN356CL (driveType = T10000b-Enc, driveFirmware = 1.52.206-5.30, sn = 572004000306) FSC: 5703||></resultText><operationalState>608</operationalState></resultStatus><currentCleanUsage>52</currentCleanUsage><maxCleanUsage>51</maxCleanUsage><faultSymptomCode>5703</faultSymptomCode><STAPacketVersion>2</STAPacketVersion></result></response>
1749 2017-12-05T04:18:34.227 1.1.-2.1.3 root hli0 move 41088401 error 3336 "Drive detected an expired clean cartridge - load retry not allowed - on load", volumeLabel=CLN356CL hliLsm=0
1750 2017-12-05T04:18:34.345 1.1.-2.1.3 root hli0 move 41088401 warn 3992 "Warning from device", Data=<response sequence="2176680" final="true"><command>rewindUnload</command><result identifier="1"><resultStatus><resultSeverity>warn</resultSeverity><resultCode>6434</resultCode><resultText><!|CDATA|drive 1,1,-2,1,3: rewindUnload Successful with Expired Cleaning Cartridge (cartLabel = CLN356CL) FSC: 5703||></resultText><operationalState>000</operationalState></resultStatus></result></response>
1874 2017-12-12T00:55:24.569 1.1.-2.1.3 root hli0 move 46272201 error 3955 "Error from device Code: 608 - Drive load failed due to expired clean cartridge", Data=<response sequence="2458949" final="true"><command>load</command><result identifier="1"><resultStatus><resultSeverity>error</resultSeverity><resultCode>6453</resultCode><resultText><!|CDATA|drive 1,1,-2,1,3: load Failed with unitCheck 5703, CartLabel = CLN357CL (driveType = T10000b-Enc, driveFirmware = 1.52.206-5.30, sn = 572004000306) FSC: 5703||></resultText><operationalState>608</operationalState></resultStatus><currentCleanUsage>52</currentCleanUsage><maxCleanUsage>51</maxCleanUsage><faultSymptomCode>5703</faultSymptomCode><STAPacketVersion>2</STAPacketVersion></result></response>
1875 2017-12-12T00:55:24.592 1.1.-2.1.3 root hli0 move 46272201 error 3336 "Drive detected an expired clean cartridge - load retry not allowed - on load", volumeLabel=CLN357CL hliLsm=0
1876 2017-12-12T00:55:24.707 1.1.-2.1.3 root hli0 move 46272201 warn 3992 "Warning from device", Data=<response sequence="2458950" final="true"><command>rewindUnload</command><result identifier="1"><resultStatus><resultSeverity>warn</resultSeverity><resultCode>6434</resultCode><resultText><!|CDATA|drive 1,1,-2,1,3: rewindUnload Successful with Expired Cleaning Cartridge (cartLabel = CLN357CL) FSC: 5703||></resultText><operationalState>000</operationalState></resultStatus></result></response>
1878 2017-12-12T01:20:21.160 1.1.-2.1.3 root hli0 move 46280801 warn 3992 "Warning from device", Data=<response sequence="2459530" final="true"><command>rewindUnload</command><result identifier="1"><resultStatus><resultSeverity>warn</resultSeverity><resultCode>6434</resultCode><resultText><!|CDATA|drive 1,1,-2,1,3: rewindUnload Successful with unitCheck 395B (cartLabel = P02171T1)||></resultText><operationalState>000</operationalState></resultStatus></result></response>
1880 2017-12-12T01:35:23.787 1.1.-2.1.3 root hli0 move 46285701 warn 3992 "Warning from device", Data=<response sequence="2459860" final="true"><command>rewindUnload</command><r

Cause

Expired cleaning cartridge.

Solution

Cleaning cartridges are expired and need to be replaced.
Acquire good cleaning cartridges, clean the drive and run drive diagnostics.

 