![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2338063.1 : ODA_BASE Causing Massive Number Of Errors To Be Logged Into /var/opt/messages Log File
mlx4_core 0000:90:00.0: Unprivileged slave 1 is trying to execute a Subnet MGMT MAD, class 0x81, method 0x1, view=Network for attr 0x15. Rejecting fill up os message file every one second on ODA 12.1.2.11 In this Document
Created from <SR 3-15652927411> Applies to:Oracle Database Appliance X6-2 HA Hardware - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. Symptoms mlx4_core 0000:90:00.0: Unprivileged slave 1 is trying to execute a Subnet MGMT MAD, class 0x81, method 0x1, view=Network for attr 0x15. Rejecting CauseWe use some wrong command check IB network status at ODA 12.1.2.11 SolutionJust ignore the message at 12.1.2.11 At 12.1.2.12 we will only do this kind of check when network has issue not every second. So the message will not filled up the os message file. At 12.2.1.2 or later we totally solve the issue. References<BUG:26738318> - DOM MESSAGE FILE FLOODED WITH: MLX4_CORE 0000:90:00.0: UNPRIVILEGED SLAVE 1<NOTE:2300740.1> - ODAVM: Upgrading to12.1.2.11 After the oda_base Startup the GI Startup Fails on Both Nodes Due to IB Failure Attachments This solution has no attachment |
||||||||||||||||||
|