![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2337764.1 : ACSLS - The Total Cell Count in ACSLS is Not in Sync with the Active Cell Count in Library
In this Document
Created from <SR 3-16334191311> Applies to:Sun StorageTek Auto Cartridge Sys Lib SW (ACSLS) - Version 7.3 to 8.4 [Release 7.0 to 8.0]Sun StorageTek SL3000 Modular Library System - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. SymptomsThe total cell count in ACSLS is not in sync with the active cell count in library after a CEM was added to expand the library. 600 cell slots should have been added to the library configuration. The free_cells.sh output still shows 1100 cells instead of 1700 cells: $ /export/home/ACSSS/utils/free_cells.sh -a ACSLS Server
ChangesCEM added in SL3000 library CauseThe new cells are not activated in SL3000 Solution1. Determine the total number of cells in the ACSLS library configuration by running 'free_cells.sh -a' $ /export/home/ACSSS/utils/free_cells.sh -a
ACS 1 Total free cells = 56 Allocated cells = 800 Total cells = 1100 ACSLS Server Total free cells = 56 Allocated cells = 800 Total cells = 1100
2. If the ACSLS total cells count is not the expected library cell count after the library expansion, verify the active cell license from the SL Console: From the SL Console, connect to the tape library.
3. Update the Actives Cells license to reflect the actual number of active cells after the library expansion a. In the Select Active Cells screen, choose "Select By - Library" and highlight a cell. This will select the entire library.
4. Configure ACSLS to include the expansion slots to the existing library configuration
Attachments This solution has no attachment |
||||||||||||||||||
|