![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||
Solution Type Problem Resolution Sure Solution 2336341.1 : Unable to Create RAID Volumes With 8-Port 12Gbps SAS-3 HBA(Estes) on X86 Servers
In this Document
Applies to:Oracle Server X6-2L - Version All Versions to All Versions [Release All Releases]Oracle Server X7-2L - Version All Versions to All Versions [Release All Releases] Oracle Server X5-2L - Version All Versions to All Versions [Release All Releases] x86 SymptomsAttempts to create a hardware RAID volume with disks attached to the 8-Port 12Gbps SAS-3 HBA(Estes) HBA result in an error and are not created. Using the sas3ircu utility to create a single disk stripe you will see the following error message: #sas3ircu 0 create 0 1:0 SAS3IRCU: The CREATE command is not supported by the firmware currently loaded on controller 0.
Using the raidconfig utility which is part of Oracle Hardware Management Pack(OHMP) #raidconfig create raid -c c0 --level 0 -d c0d0 CauseThe firmware supported on these cards is of the type IT(initiator-target) and does not support integrated RAID. IR(integrated raid) firmware is not supported for this HBA SolutionIf there is a need to create hardware RAID volumes then the 8-Port 12Gbps SAS-3 RAID HBA(Aspen) or 16-Port 12Gbps SAS-3 RAID HBA(Vail) should be used. Otherwise a software RAID solution can be used. Attachments This solution has no attachment |
||||||||||||||||
|