Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2335780.1
Update Date:2018-05-17
Keywords:

Solution Type  Problem Resolution Sure

Solution  2335780.1 :   SPARC T8-1, SPARC T8-2 and SPARC T8-4, onboard network interfaces not visible in Solaris after installation  


Related Items
  • SPARC T8-1
  •  
  • SPARC T8-4
  •  
  • SPARC T8-2
  •  
Related Categories
  • PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T8
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-16336657981>

Applies to:

SPARC T8-1 - Version All Versions to All Versions [Release All Releases]
SPARC T8-2 - Version All Versions to All Versions [Release All Releases]
SPARC T8-4 - Version All Versions to All Versions [Release All Releases]
Oracle Solaris on SPARC (64-bit)
Information in this document applies to any platform.

Symptoms

After installation of Oracle Solaris 11.3 image on Sparc T8-1, Sparc T8-2 or Sparc T8-4 Servers the onboard Network interfaces are not visible (configured) in Solaris.

  • no faults have been reported
  • in OS, no entries for the devices exist in /etc/path_to_inst
  • prtdiag shows the network interface devices, but they are not configured:

======================================== IO Devices =======================================
Slot +            Bus   Name +                            Model      Max Speed  Cur Speed
Status            Type  Path                                         /Width     /Width
-------------------------------------------------------------------------------------------
/SYS/MB/XGBE      PCIE  network-pciex8086,1589                       8.0GT/x8   8.0GT/x8
                        /pci@300/pci@1/network
/SYS/MB/NET1      PCIE  network-pciex8086,1589                       8.0GT/x8   8.0GT/x8
                        /pci@300/pci@1/network
/SYS/MB/NET2      PCIE  network-pciex8086,1589                       8.0GT/x8   8.0GT/x8
                        /pci@300/pci@1/network
/SYS/MB/NET3      PCIE  network-pciex8086,1589                       8.0GT/x8   8.0GT/x8
                        /pci@300/pci@1/network

 

Cause

T8 Systems require minimum OS release of Solaris 11.3 SRU 24 or later.
With installation images Solaris 11.3 SRU24 or later, required hardware drivers are included and the interfaces will be configured.

# grep /pci@300/pci@1/network /etc/path_to_inst

"/pci@300/pci@1/network@0" 0 "i40e"
"/pci@300/pci@1/network@0,1" 1 "i40e"
"/pci@300/pci@1/network@0,2" 2 "i40e"
"/pci@300/pci@1/network@0,3" 3 "i40e"


# prtdiag

======================================== IO Devices =======================================
Slot +            Bus   Name +                            Model      Max Speed  Cur Speed
Status            Type  Path                                         /Width     /Width
-------------------------------------------------------------------------------------------
/SYS/MB/XGBE      PCIE  network-pciex8086,1589                       8.0GT/x8   8.0GT/x8
                        /pci@300/pci@1/network@0
/SYS/MB/NET1      PCIE  network-pciex8086,1589                       8.0GT/x8   8.0GT/x8
                        /pci@300/pci@1/network@0,1
/SYS/MB/NET2      PCIE  network-pciex8086,1589                       8.0GT/x8   8.0GT/x8
                        /pci@300/pci@1/network@0,2
/SYS/MB/NET3      PCIE  network-pciex8086,1589                       8.0GT/x8   8.0GT/x8
                        /pci@300/pci@1/network@0,3

 

Solution

Use Solaris 11.3 SRU 24 or later installation image, links to installation images are provided in Doc ID 2045311.1.
In case the interfaces are still missing after installation of Solaris 11.3 SRU 24 or later, please open a Service Request.

 

Reference: SPARC T8 Series Servers Product Notes

 