SPARC T8-1, SPARC T8-2 and SPARC T8-4, onboard network interfaces not visible in Solaris after installation
Related Items |
- SPARC T8-1
- SPARC T8-4
- SPARC T8-2
|
Related Categories |
- PLA-Support>Sun Systems>SPARC>CMT>SN-SPARC: T8
|
In this Document
Created from <SR 3-16336657981>
Applies to:
SPARC T8-1 - Version All Versions to All Versions [Release All Releases]
SPARC T8-2 - Version All Versions to All Versions [Release All Releases]
SPARC T8-4 - Version All Versions to All Versions [Release All Releases]
Oracle Solaris on SPARC (64-bit)
Information in this document applies to any platform.
Symptoms
After installation of Oracle Solaris 11.3 image on Sparc T8-1, Sparc T8-2 or Sparc T8-4 Servers the onboard Network interfaces are not visible (configured) in Solaris.
- no faults have been reported
- in OS, no entries for the devices exist in /etc/path_to_inst
- prtdiag shows the network interface devices, but they are not configured:
======================================== IO Devices =======================================
Slot + Bus Name + Model Max Speed Cur Speed
Status Type Path /Width /Width
-------------------------------------------------------------------------------------------
/SYS/MB/XGBE PCIE network-pciex8086,1589 8.0GT/x8 8.0GT/x8
/pci@300/pci@1/network
/SYS/MB/NET1 PCIE network-pciex8086,1589 8.0GT/x8 8.0GT/x8
/pci@300/pci@1/network
/SYS/MB/NET2 PCIE network-pciex8086,1589 8.0GT/x8 8.0GT/x8
/pci@300/pci@1/network
/SYS/MB/NET3 PCIE network-pciex8086,1589 8.0GT/x8 8.0GT/x8
/pci@300/pci@1/network
Cause
T8 Systems require minimum OS release of Solaris 11.3 SRU 24 or later.
With installation images Solaris 11.3 SRU24 or later, required hardware drivers are included and the interfaces will be configured.
# grep /pci@300/pci@1/network /etc/path_to_inst
"/pci@300/pci@1/network@0" 0 "i40e"
"/pci@300/pci@1/network@0,1" 1 "i40e"
"/pci@300/pci@1/network@0,2" 2 "i40e"
"/pci@300/pci@1/network@0,3" 3 "i40e"
# prtdiag
======================================== IO Devices =======================================
Slot + Bus Name + Model Max Speed Cur Speed
Status Type Path /Width /Width
-------------------------------------------------------------------------------------------
/SYS/MB/XGBE PCIE network-pciex8086,1589 8.0GT/x8 8.0GT/x8
/pci@300/pci@1/network@0
/SYS/MB/NET1 PCIE network-pciex8086,1589 8.0GT/x8 8.0GT/x8
/pci@300/pci@1/network@0,1
/SYS/MB/NET2 PCIE network-pciex8086,1589 8.0GT/x8 8.0GT/x8
/pci@300/pci@1/network@0,2
/SYS/MB/NET3 PCIE network-pciex8086,1589 8.0GT/x8 8.0GT/x8
/pci@300/pci@1/network@0,3
Solution
Use Solaris 11.3 SRU 24 or later installation image, links to installation images are provided in Doc ID 2045311.1.
In case the interfaces are still missing after installation of Solaris 11.3 SRU 24 or later, please open a Service Request.
Reference: SPARC T8 Series Servers Product Notes