2333451.1
:
SL48 - Robotic No Response Error, FSC 80 B5
Related Items |
- Sun StorageTek SL48 Tape Library
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: OEM Drive and Library
|
In this Document
Created from <SR 3-16232132731>
Applies to:
Sun StorageTek SL48 Tape Library - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Symptoms
SL48 library robotic no response error.
FSC 80 B5
17.11.22 03:33:35.86 Libctrl task Error - HE: robotic no response
Return status: 0x80 - command failed
Global error code: 0xB5 - HE: robotic no response
Module error code: 0x40, 64
Current command: 0x15 - move cartridge
Task originator: 0x02 - CDB interpreter task
Extender library specifier: 0x00 - master library
Source element type.: 0x04 - tape drive
Element number: 0x01, 1
Destination element type.: 0x02 - storage slot
Element number: 0x2B, 43
Component ID type: 0x02 - medium PVT (barcode)
Component ID: 0P0017L4
Cause
Cause is undetermined.
Solution
- Upgrade the library firmware to latest version.
- Power-cycle the unit and check the library functionality.
- Run the wellness tests.