Solution Type  Problem Resolution Sure

Solution  2332973.1 :   BDA: bdacheckcluster fails with the "ERROR: Wrong bda-monitor status : bda monitor is stopped"  


Related Items
  • Big Data Appliance X5-2 Starter Rack
  •  
Related Categories
  • PLA-Support>Eng Systems>BDA>Big Data Appliance>DB: BDA_EST
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-16224168611>

Applies to:

Big Data Appliance X5-2 Starter Rack - Version All Versions and later
Linux x86-64

Symptoms

bdacheckcluster shows that the BDA Monitor is stopped on one or nodes.  Output looks like: 

# bdacheckcluster
  
...
XXXX: ERROR: Wrong bda-monitor status : bda monitor is stopped
...
XXXX: ERROR: Big Data Appliance failed software validation checks
...

 

Cause

 The cause is that the bda-monitor service is not running.

Solution

On the node where the BDA Monitor is not running, start it:

# service bda-monitor start

Verify it is started: 

# service bda-monitor status
  
bda monitor is running

  