Solution Type Problem Resolution Sure Solution 2332973.1 : BDA: bdacheckcluster fails with the "ERROR: Wrong bda-monitor status : bda monitor is stopped"
In this Document
Created from <SR 3-16224168611> Applies to:Big Data Appliance X5-2 Starter Rack - Version All Versions and laterLinux x86-64 Symptomsbdacheckcluster shows that the BDA Monitor is stopped on one or nodes. Output looks like: # bdacheckcluster
... XXXX: ERROR: Wrong bda-monitor status : bda monitor is stopped ... XXXX: ERROR: Big Data Appliance failed software validation checks ...
CauseThe cause is that the bda-monitor service is not running. SolutionOn the node where the BDA Monitor is not running, start it: # service bda-monitor start
Verify it is started: # service bda-monitor status
bda monitor is running