Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2332788.1
Update Date:2017-12-01
Keywords:

Solution Type  Problem Resolution Sure

Solution  2332788.1 :   T10000B- Unable To Read From Tape, FSC 4055  


Related Items
  • Sun StorageTek T10000B Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Cause
Solution
References


Created from <SR 3-16183291616>

Applies to:

Sun StorageTek T10000B Tape Drive - Version All Versions and later
Information in this document applies to any platform.

No SNO and No perm errors and the drive is at version : 1.50.203.

Symptoms

Hostname: not_applicable
Product Type: T10000B
Summary:Unable to read from tape.

Fault event description:Unable to read from tape.
receiver_id: SDP2-2.4
siteID: 1487867965088.0
Unable to read from tape.
************* ADDITIONAL INFORMATION *************
*** Alarm Description ***
 FSC(4055): Unable to read from tape.
Unable to read from tape.
Device Dmod: XXXXXXXXXXXX
Tray SN: XXXXXXXXXXXX
Device Model: T10000B
Trap Type: tapenewpermlog
Locator Text: ACS/LSM/Pnl/Drv: 0/0/0/0, Library: SL8500 : acs02, Drive Location: XXXXXXXX
FSCs:
 4055:null
 4055:null
 4055:null

Cause

FSC Exact Match Found)
FSC: 4055 RO_FSC_READ_PAST_HLUID_OR_SYNC
MIM Code: NONE
FRU: MICROCODE CONF: 100%
Summary: |INVALID UCODE |FUNC NOT IMPL | *** |
Field Text:
Unable to read from tape.

Solution

Suggest Customer to Inspect the media if the tape is failing with multiple drives.

If the media failed with a single drive and generated FSC : 4055, ask Customer to Inspect the media.

Ask Customer to upgrade to the latest drive firmware.  Provide the patch number to customer to download.

If media is working fine with the other drives and drive is at the latest firmware level, collect the drive dump and upload the information to the service request for review.
 

References

<NOTE:2178310.1> - T10000B - REPORTED READ DATA CHK: 08402023174528203700"4056 4056 4056 4056"

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback