![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2332788.1 : T10000B- Unable To Read From Tape, FSC 4055
In this Document
Created from <SR 3-16183291616> Applies to:Sun StorageTek T10000B Tape Drive - Version All Versions and laterInformation in this document applies to any platform. No SNO and No perm errors and the drive is at version : 1.50.203. SymptomsHostname: not_applicable CauseFSC Exact Match Found) SolutionSuggest Customer to Inspect the media if the tape is failing with multiple drives. If the media failed with a single drive and generated FSC : 4055, ask Customer to Inspect the media. Ask Customer to upgrade to the latest drive firmware. Provide the patch number to customer to download. If media is working fine with the other drives and drive is at the latest firmware level, collect the drive dump and upload the information to the service request for review. References<NOTE:2178310.1> - T10000B - REPORTED READ DATA CHK: 08402023174528203700"4056 4056 4056 4056"Attachments This solution has no attachment |
||||||||||||||||||
|