Asset ID: |
1-72-2332508.1 |
Update Date: | 2017-11-28 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2332508.1
:
T10000C - VSM23/24N3 RTD=01C6 FSC=FE01 Drive Not Operational
Related Items |
- StorageTek T10000C Tape Drive
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
|
In this Document
Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for service personnel
Created from <SR 3-16190167077>
Applies to:
StorageTek T10000C Tape Drive - Version All Versions and later
Information in this document applies to any platform.
Symptoms
FICON Drive SNO FSC is FE01, ITZ_FSC_DC_CMPR_DIAGNOSTIC_FAILED
A drive fatal error (SNO) has occurred.
11/16/2017 03:02:57 PM 03:02:57 PM JOB39765 OPSOSF S57 SY57 SLS0699I Response ACS 00 SEQ 01/241 ERR 10/02 Drive Is Not Operational Ret d To Src LSM 04 OPS NULL SY57 363203 0 N
11/16/2017 03:02:57 PM 03:02:57 PM JOB39657 OPSOSF S57 SY57 SLS0698I Req ACS 00 SEQ 01/241 REQ B Mount VOL V30923 SRC 04/08:14:00 CEL TGT 04/01:02:00 DRV 1C6 OPS NULL SY57 363204 0 N
11/16/2017 03:02:58 PM 03:02:58 PM HSC HSC S57 SY57 SLS6628E RTD V23R01C6 on VTSS TVSM23N3 failed to mount MVC V30923 OPS NULL SY57 363205 0 N
11/16/2017 03:02:58 PM 03:02:58 PM JOB39657 OPSOSF S57 SY57 SLS6684I RTD V23R01C6 on VTSS TVSM23N3 Returned ECAM error CC=9 RC=128 OPS NULL SY57 363206 0 N
11/16/2017 03:02:58 PM 03:02:58 PM JOB39765 OPSOSF S57 SY57 SLS6693I RTD V23R01C6 Failed, drive will be retried later OPS NULL SY57 363207 0 N
11/16/2017 03:02:59 PM 03:02:59 PM JOB39657 OPSOSF S57 SY57 SLS6684I RTD V24R01C6 on VTSS TVSM24N3 Returned ECAM error CC=5 RC=109 OPS NULL SY57 363208 0 N
11/16/2017 03:04:00 PM 03:04:00 PM JOB39657 OPSOSF S57 SY57 SLS6684I RTD V23R01C6 on VTSS TVSM23N3 Returned ECAM error CC=5 RC=109 OPS NULL SY57 363210 0 N
Cause
Defective drive.
Solution
Replaced the drive.
Bug 27132600
Attachments
This solution has no attachment