Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2332508.1
Update Date:2017-11-28
Keywords:

Solution Type  Problem Resolution Sure

Solution  2332508.1 :   T10000C - VSM23/24N3 RTD=01C6 FSC=FE01 Drive Not Operational  


Related Items
  • StorageTek T10000C Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for service personnel
Created from <SR 3-16190167077>

Applies to:

StorageTek T10000C Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

FICON Drive SNO FSC is FE01, ITZ_FSC_DC_CMPR_DIAGNOSTIC_FAILED

A drive fatal error (SNO) has occurred.

11/16/2017 03:02:57 PM 03:02:57 PM JOB39765 OPSOSF S57 SY57 SLS0699I Response ACS 00 SEQ 01/241 ERR 10/02 Drive Is Not Operational Ret d To Src LSM 04 OPS NULL SY57 363203 0 N
11/16/2017 03:02:57 PM 03:02:57 PM JOB39657 OPSOSF S57 SY57 SLS0698I Req ACS 00 SEQ 01/241 REQ B Mount VOL V30923 SRC 04/08:14:00 CEL TGT 04/01:02:00 DRV 1C6 OPS NULL SY57 363204 0 N
11/16/2017 03:02:58 PM 03:02:58 PM HSC HSC              S57 SY57 SLS6628E RTD V23R01C6 on VTSS TVSM23N3 failed to mount MVC V30923 OPS NULL SY57 363205 0 N
11/16/2017 03:02:58 PM 03:02:58 PM JOB39657 OPSOSF S57 SY57 SLS6684I RTD V23R01C6 on VTSS TVSM23N3 Returned ECAM error CC=9 RC=128 OPS NULL SY57 363206 0 N
11/16/2017 03:02:58 PM 03:02:58 PM JOB39765 OPSOSF S57 SY57 SLS6693I RTD V23R01C6 Failed, drive will be retried later OPS NULL SY57 363207 0 N
11/16/2017 03:02:59 PM 03:02:59 PM JOB39657 OPSOSF S57 SY57 SLS6684I RTD V24R01C6 on VTSS TVSM24N3 Returned ECAM error CC=5 RC=109 OPS NULL SY57 363208 0 N
11/16/2017 03:04:00 PM 03:04:00 PM JOB39657 OPSOSF S57 SY57 SLS6684I RTD V23R01C6 on VTSS TVSM23N3 Returned ECAM error CC=5 RC=109 OPS NULL SY57 363210 0 N

Cause

 Defective drive.

Solution

Replaced the drive.

Bug 27132600


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback