Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2332289.1
Update Date:2018-03-22
Keywords:

Solution Type  Problem Resolution Sure

Solution  2332289.1 :   Oracle ZFS Storage Appliance: How To Resolve Replication Stage 'init' Failed: Failed To Contact Target  


Related Items
  • Sun ZFS Storage 7320
  •  
  • Oracle ZFS Storage ZS5-4
  •  
  • Oracle ZFS Storage ZS3-2
  •  
  • Oracle ZFS Storage ZS3-4
  •  
  • Sun ZFS Storage 7420
  •  
  • Oracle ZFS Storage ZS5-2
  •  
  • Oracle ZFS Storage ZS4-4
  •  
  • Sun ZFS Storage 7120
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: ZS-ES
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Created from <SR 3-16224563251>

Applies to:

Sun ZFS Storage 7420 - Version All Versions to All Versions [Release All Releases]
Sun ZFS Storage 7320 - Version All Versions to All Versions [Release All Releases]
Sun ZFS Storage 7120 - Version All Versions to All Versions [Release All Releases]
Oracle ZFS Storage ZS3-2 - Version All Versions to All Versions [Release All Releases]
Oracle ZFS Storage ZS3-4 - Version All Versions to All Versions [Release All Releases]
7000 Appliance OS (Fishworks)

Symptoms

After AKD upgrade, replications failed - errmsg = stage 'init' failed: failed to contact target.

 

Changes

The appliance firmware was upgraded from  2013.1.6.13  to  2013.1.6.15

 

Cause

Upgrade broke the replication software links in AKD.

 

Solution

Resolved by AKD  restart on the source ZFS appliance ( Maintenance > System > Restart ).

 

 

References

<BUG:26827305> - REPLICATION FAILURE: STAGE 'INIT' FAILED: FAILED TO CONTACT TARGET

Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback