Solution Type Problem Resolution Sure Solution 2332289.1 : Oracle ZFS Storage Appliance: How To Resolve Replication Stage 'init' Failed: Failed To Contact Target
In this Document
Created from <SR 3-16224563251> Applies to:Sun ZFS Storage 7420 - Version All Versions to All Versions [Release All Releases]Sun ZFS Storage 7320 - Version All Versions to All Versions [Release All Releases] Sun ZFS Storage 7120 - Version All Versions to All Versions [Release All Releases] Oracle ZFS Storage ZS3-2 - Version All Versions to All Versions [Release All Releases] Oracle ZFS Storage ZS3-4 - Version All Versions to All Versions [Release All Releases] 7000 Appliance OS (Fishworks) SymptomsAfter AKD upgrade, replications failed - errmsg = stage 'init' failed: failed to contact target.
ChangesThe appliance firmware was upgraded from 2013.1.6.13 to 2013.1.6.15
CauseUpgrade broke the replication software links in AKD.
SolutionResolved by AKD restart on the source ZFS appliance ( Maintenance > System > Restart ).
References<BUG:26827305> - REPLICATION FAILURE: STAGE 'INIT' FAILED: FAILED TO CONTACT TARGETAttachments This solution has no attachment |
||||||||||||||||||||
|