![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2330460.1 : 6300/3900 SBC server stops sending data to Oracle Communication Session Monitor
In this Document
Created from <SR 3-16131096711> Applies to:Acme Packet 6300 - Version S-Cz7.3.0 and laterOracle Communications Session Monitor - Version 3.3.x and later Acme Packet 3900 - Version E-Cz7.4.0 and later Information in this document applies to any platform. Symptoms6300/3900 SBC server(s) configured as SBC probes for Oracle Communications Session Monitor stops sending data (though originally this was working) The SBC's log file: log.commMonitord may show: CommMonitorServerReq::process: no agent for socket
And output from the command "show comm-monitor" will show an increase in the "internal msg dropped" counter e.g. SBC-EST-1# sho comm-monitor 13:03:08-179 CommMonitor Socket Statistics ---- Lifetime ---- CommMonitor Statistics ---- Lifetime ----
NOTE: The steps outlined in document: Oracle Communications Session Monitor/Palladion stopped displaying traffic from the SBC - the SBC stopped sending traffic to OCSM/Palladion (after a High Availability switchover) (Doc ID 1984646.1) do not resolve the issue
CauseTracked in Defect # 27031977 SolutionThere is no current solution to the issue. The work-around is to delete the whole comm-monitor section e.g NOTE: Run the command: show running-config system-config
first and make note of the current settings for the comm-monitor section
# configure terminal
(configure)# system system-config (system-config)# select (system-config)# comm-monitor (comm-monitor)# select (comm-monitor)# no (comm-monitor)# done (comm-monitor)# exit (system-config)# exit Save Changes [y/n]?: y **(system)# exit **(configure)# exit
and save and activate the change. Next, re-enter the comm-monitor section and save and activate again. If this does not resolve the issue, then a reboot will be needed.
References<NOTE:1984646.1> - Oracle Communications Session Monitor/Palladion stopped displaying traffic from the SBC - the SBC stopped sending traffic to OCSM/Palladion (after a High Availability switchover)<BUG:27031977> - SBC NOT SENDING DATA TO OCOM Attachments This solution has no attachment |
||||||||||||||||||
|