Asset ID: |
1-72-2329083.1 |
Update Date: | 2017-11-22 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2329083.1
:
EPAP A Logs Directory Is 95% Full
Related Items |
- Oracle Communications EAGLE (Hardware)
|
Related Categories |
- PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec OS EPAP ECAP
|
In this Document
Created from <SR 3-16182854663>
Applies to:
Oracle Communications EAGLE (Hardware) - Version EPAP 16.1 and later
Information in this document applies to any platform.
Symptoms
Error raised because /var/TKLC/epap/logs partition is running out of space
Cause
Debug level set to 200.
High debug level caused large volume of logging that created new log files frequently
Solution
Delete files and turn down debugging to 50.
Attachments