Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2328064.1
Update Date:2018-05-17
Keywords:

Solution Type  Problem Resolution Sure

Solution  2328064.1 :   SL3000 - INVALID Partition Due to INACTIVE Cells  


Related Items
  • Sun StorageTek SL3000 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  


HOST is not able to access SL3000 library due to INVALID PARTITION

In this Document
Symptoms
Cause
Solution


Created from <SR 3-16157488263>

Applies to:

Sun StorageTek SL3000 Modular Library System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

FRS_4.40

Symptoms

HOST is not able to access SL3000 library.

Customer rebooted library but still get the warning about active cell count.

INVALID PARTITION
INACTIVE CELLS

ALL CELLS are in INACTIVE STATUS FROM ALL PARTITIONS (3)

Cause

Storage cells are in INACTIVE STATUS
 
Partition corruption
 

Solution

Delete free cell(s) from partition-1.
Verify cell status in partition report CellSummaryReport that cells are ACTIVE now.
Add previously removed cell(s) back to partition-1.
Verify main partition in SLC under System Details that is is valid now.

Vary SL3000 library back online to application and test access.
 

 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.