Solution Type  Problem Resolution Sure

Solution  2325344.1 :   T10000D - 4.13.101 Microcode Changes  


Related Items
  • StorageTek T10000D Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Changes
Cause
Solution


Applies to:

StorageTek T10000D Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Define problems addressed in released 4.13.101 microcode.

Changes

 

Cause

 Define problems addressed in released 4.13.101 microcode.

Solution

 4.13.101 microcode changes:

Bug Number
FSC
Synopsis
26391408
2B31
Fix for certain types of 2B31 SNO failures.
26432358
DC56
Fix for a DC56 SNO failure. This scenario is associated to a position to EOD command by OHSM.
26497496
NONE
Patch to gsoap for issue CVE-2017-9765.
26387315
3947
This change will now eliminate a specific problem resulting previously in a 3947 SNO. Now for this scenario a new FSC 3919 will be reported. The 3919 is not a SNO. If a 3919 error occurs, the drive will retry the write. If the retries fail then a perm 3919 error will result and the drive should be replaced for a hardware problem.
26378004
3001
Fix for a specific 3001 SNO scenario that was determined to be a code bug.
26371163
4C02
Fix for a specific 4C02 SNO scenario. This replaces special build RC412106 code.
26241430 26173727
6106 6101
This fixes an introduced bug where 6106 and 6101 PERM errors were being reported only at DPKM running encryption sites. This replaces special build RB412106 code.

26085463
NONE
This fixes an introduced code bug (seen with 4.12.106 code) where the FE’s reported they could no longer save the drive/s configuration table as a file with VOP to use to restore the configuration file to any T10KD drive/s.
25690831
4080
Customer tapes previously getting read perm/SNO errors with 4080 FSC will now read without 4080 errors.
25684516
Fixes a SNO 343B trying to read un-reconstituted sparse data.
26899468
3F24
Fixes for different 3F24 read perm errors exhausting read accumulation.
26560147
RFE
Service requested engineering for a new code change to down drives for these four FSC’s related to reel motor failures that have been known to expose the customers tape to potential physical damage. These four FSC’s are 590F, 5911, 550C and 550D. One time failures will now prevent any/all subsequent load requests and these drive must be replaced and sent through service repair.

27054996

GRAO/RAO

Addresses a problem where the drive hangs when using GRAO/RAO with tapes that have a small amount of data written to them.