Solution Type Problem Resolution Sure Solution 2323743.1 : ES2-64 Switch did not come up after a Power Cycle
In this Document
Created from <SR 3-15970621940> Applies to:Oracle Ethernet Switch ES2-64 - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform. SymptomsES2-64 switch did not come up after a power cycle. CauseILOM POWER settings not configured . SolutionConfigure ILOM as described in the ES2-64 Product notes. Set 'HOST_AUTO_POWER_ON' to 'enabled'
Confirm by doing a power cycle on the switch again by removing and reinserting AC power cables. If the issue persists, open an SR with Oracle.
Attachments This solution has no attachment |
||||||||||||||||
|