![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2322566.1 : Exalytics: Transforming HFM classic application to EPMA Errors With "Unable to run transforms on common schema."
In this Document
Created from <SR 3-15905760771> Applies to:Hyperion Financial Management - Version 11.1.2.4.103 and laterExalytics In-Memory Machine X6-4 - Version All Versions to All Versions [Release All Releases] Information in this document applies to any platform. SymptomsWhile trying to transform HFM classic application to EPMA getting below error : Tue Oct 10 07:04:57 EDT 2017 CORPHFM: Starting Transformation
Note Here HFM and EPMA components are configured in different schemas ( HFM and EPMA).
CauseCause of this issue has been identified and verified as:
SolutionTo fix this issue ,do one of the below options: Option 1: Attachments This solution has no attachment |
||||||||||||||||||
|