Solution  2320895.1 :   ERROR: Failure From Drive Code: 604 - Drive Is Not Functional - 1,2,1,1,1 Drive  


Related Items
  • StorageTek T10000D Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for service personnel
Created from <SR 3-15997289247>

Applies to:

StorageTek T10000D Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Drive health test Failed ERROR: Failure from drive Code: 604 - Drive is not functional - 1,2,1,1,1 drive.
Final test conclusion Failed ERROR! Problems detected during system check diagnostic.

Drive_Bay46(1.2.1.1.1)
3955 - (154X)
Error from device Code: 604 - Drive is not functional, drive 1,2,1,1,1: getState FAILED, resultCode = 6457
(Errors Started - 2017-10-23 14:24:11 Errors Stopped - 2017-10-24 11:33:40)

Cause

 Drive is defective.

Solution

Replace the tape drive