Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2319576.1
Update Date:2017-10-23
Keywords:

Solution Type  Problem Resolution Sure

Solution  2319576.1 :   LTO5 - Drive 1,2,1,1,31(ACSLS Drive 0,1,1,10) Often Reads Header Failed In Netvault.  


Related Items
  • LTO Tape Drive
  •  
  • IBM LTO5 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: OEM Drive and Library
  •  




In this Document
Symptoms
Cause
Solution
 Applies to:


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Confidential for service personnel
Created from <SR 3-15931185237>

Applies to:

IBM LTO5 Tape Drive - Version All Versions and later
LTO Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

LTO5 drive 1,2,1,1,31(ACSLS drive 0,1,1,10) often reads, header failed in Netvault.

It can mount media but cannot successfully read tape headers.

7060: C2 Uncorrectable Error.

Drive is taking excessive hard R/W errors. Cleaning has not resolved the issue.

Cause

38 7060: C2 Uncorrectable Error FUJIFILM 3JRPTJ4G G360 (pf160306) 7060: C2 Uncorrectable Error 00h 50 0a 09 80 00 81 e5 e8 8 35 6: Drive or Media 650426856 0d 07h:28m:38s MK4701L5 MK4701L5 69
39 7060: C2 Uncorrectable Error FUJIFILM 8EPX5803 G360 (pf160306) 7060: C2 Uncorrectable Error 00h 50 0a 09 80 00 81 e5 e8 91 35 6: Drive or Media 088409406 0d 07h:42m:23s MF7688L5 29

Solution

Replace defective drive.

Applies to:

IBM LTO5 Tape Drive
1-914CU


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.