Solution Type Problem Resolution Sure Solution 2319576.1 : LTO5 - Drive 1,2,1,1,31(ACSLS Drive 0,1,1,10) Often Reads Header Failed In Netvault.
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:IBM LTO5 Tape Drive - Version All Versions and laterLTO Tape Drive - Version All Versions and later Information in this document applies to any platform. SymptomsLTO5 drive 1,2,1,1,31(ACSLS drive 0,1,1,10) often reads, header failed in Netvault. It can mount media but cannot successfully read tape headers. 7060: C2 Uncorrectable Error. Drive is taking excessive hard R/W errors. Cleaning has not resolved the issue. Cause38 7060: C2 Uncorrectable Error FUJIFILM 3JRPTJ4G G360 (pf160306) 7060: C2 Uncorrectable Error 00h 50 0a 09 80 00 81 e5 e8 8 35 6: Drive or Media 650426856 0d 07h:28m:38s MK4701L5 MK4701L5 69 SolutionReplace defective drive. Applies to:IBM LTO5 Tape Drive Attachments This solution has no attachment |
||||||||||||||||||
|