Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2319467.1
Update Date:2017-11-12
Keywords:

Solution Type  Problem Resolution Sure

Solution  2319467.1 :   E5-MS Resync Issues After Upgrade to 46.3.x  


Related Items
  • Oracle Communications EAGLE (Software)
  •  
Related Categories
  • PLA-Support>Sun Systems>CommsGBU>Global Signaling Solutions>SN-SND: Tekelec EMS
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-15842524851>

Applies to:

Oracle Communications EAGLE (Software) - Version E5-MS 46.3 and later
Information in this document applies to any platform.

Symptoms

After the E5-MS R46.3.0.0.1 upgrade, the Eagle alarm resync failed.
When running Eagle resync from Eagle Discovery, you may receive this message from OCEEMS notifications:-

Alarm resynchronization failed for EAGLE: <clli> initiated by user: <username>!

OCEEMS cannot connect to EAGLE: <clli> for receiving alarms!

The Eagle Discovery Protocol is SSH and Fault Interface is SNMP. 

Cause

The issue can occur for the following reason:

  1. Invalid Eagle login ID/password.
  2. Invalid ssh key information.

 

Solution

To implement the solution, do the following:

  1. Retrieve the login-ID/password configured for Eagle Discovery and verify it from E5-MS server command line to ensure successful log into the Eagle with no issue.  If login-ID/password no longer valid, reset the password or re-create a new login-ID is required.
  2. If issue persist, proceed to renew the ssh key information on E5-MS server. Login as E5-MS administrator eg. "e5msadm" and execute the command "ssh-keygen -R <Eagle IP Address of IPSM and OAM>".  Example:  
    • [e5msadm@app]$ ssh-keygen -R 192.168.1.123
    • /home/e5msadm/.ssh/known_hosts updated.
    • Original contents retained as /home/e5msadm/.ssh/known_hosts.old
     
  3. Login to E5-MS GUI and perform Eagle Discovery.
  4. Verify if alarm resync successfully. Resync status can be checked in OCEEMS Notifications.


 