![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2318967.1 : SL3000 - CAP in Use by Another Requester
In this Document
Created from <SR 3-15892662141> Applies to:Sun StorageTek SL3000 Modular Library System - Version Not Applicable to Not Applicable [Release N/A]Information in this document applies to any platform. Symptoms"CAP is in use by another requester" "CAP is unavailable", CAP=1,1,5,2,1 CauseAs a general rule, attempts to manually move tapes to and from the CAP should not be done; typically this is only done to move cleaning tapes into the system cells. SolutionManual moves of data cartridges to and from the CAP should not be done. The Host should manage all CAP operations for customer data cartridges, the library cartridge database has to be managed by the Host to keep the cartridge database in sync and accessible. This message indicates the CAP was reserved to a host when a manual move operation was attempted. Since the CAP is architected as a shared resource CAP operations is only allowed by the Reserver of the CAP. References<NOTE:1643391.1> - SL3000 - Base Module FAN Failure: How to Replace ECM BASE FAN Module Assembly<NOTE:2156325.1> - SL3000 - Library Unable To Communicate With ACSLS Server on Installation - Msg "Cap in use by another requester" Attachments This solution has no attachment |
||||||||||||||||||
|