![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2318665.1 : Oracle ZFS Storage Appliance: SRA Discover Devices failed with Unknown Error (SRA_EUNKNOWN) after upgrade to OS 8.7.x
In this Document
Created from <SR 3-15939310452> Applies to:Sun ZFS Storage 7320 - Version All Versions and laterSun ZFS Storage 7120 - Version All Versions and later Sun Storage 7410 Unified Storage System - Version All Versions and later Sun Storage 7310 Unified Storage System - Version All Versions and later Sun Storage 7210 Unified Storage System - Version All Versions and later 7000 Appliance OS (Fishworks) SymptomsAfter upgrade to OS 8.7.x, SRA Discover Devices failed with Unknown Error (SRA_EUNKNOWN).
Error similar to the following are reported in SRA logs : Dispatching...
Screenshot of the error from Array Manager :
ChangesAK revision upgraded from 8.6.x to 8.7.x
CauseThe causes of this problem are : 1. Key size supported by Java. 2. JVM do not support the new key exchange algorithm needed to SSH into the appliance with AK 8.7
Also JVM that is bundled with SRM does not support the new key exchange algorithm needed to SSH into the appliance with AK 8.7.
SolutionInstall Java 8 for SRM, so the plugin will use the system Java and should work. Edit the java.config file to say 'true' in SRM . Note: If you want to use the System Java for SRM, the java.config file must be edited to say 'true'. Otherwise the plugin will use the version of Java that is bundled with SRM.
References<BUG:25145253> - CANNOT ADD ARRAY OS 8.7Attachments This solution has no attachment |
||||||||||||||||||||
|