Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2318452.1
Update Date:2017-10-20
Keywords:

Solution Type  Problem Resolution Sure

Solution  2318452.1 :   ACSLS - Drive Replaced But Cannot be Configured Using 'config drives' or 'config acs'  


Related Items
  • Sun StorageTek T10000B Tape Drive
  •  
  • Sun StorageTek Auto Cartridge Sys Lib SW (ACSLS)
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: Tape Library Control Software
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-15922994371>

Applies to:

Sun StorageTek T10000B Tape Drive - Version All Versions to All Versions [Release All Releases]
Sun StorageTek Auto Cartridge Sys Lib SW (ACSLS) - Version 8.2 to 8.2 [Release 8.0]
Information in this document applies to any platform.

Symptoms

An LTO4 drive is replaced with a T10KD drive.

The drive is showing online on the SLConsole.

'config drives 1,3,1'  is timing out and logging this message in acsss_event.log:


2017-10-12 20:03:45 ACSCFG[36296]:
126 N cfg_drv_state.c 1 1006
cfg_drv_state:st_req_error: Timed out waiting for message

2017-10-12 20:03:45 ACSSA[0]:
1435 W sa_demux.c 1 296
Unable to handle unusual status or event. See related messages.


'config acs 1' ends in a similar manner:


--
2017-10-12 22:59:17 ACSCFG[40576]:
126 N cfg_acs_state.c Unknown 309
cfg_acs_state:st_req_error: Timed out waiting for message

 
The acslh trace does not show any packets related to the config commands. The
config command ends with a STATUS_PROCESS_FAILURE:

-
$ config drives 1,3,1
  2017-10-12 20:40:30

  Obtaining Configuration details, please wait
Dynamic config failed with status STATUS_PROCESS_FAILURE


---



These are the error messages right after the drive is replaced and varied online:

2017-10-12 14:15:28 VARY[29137]:
126 N va_drv_stat.c 1 801
va_drv_states:st_req_error: Timed out waiting for message

2017-10-12 14:15:28 ACSSA[0]:
1435 W sa_demux.c 1 296
Unable to handle unusual status or event. See related messages.

2017-10-12 14:15:29 ACSLM[0]:
922 N lm_wait_proc.c 1 436
lm_wait_proc: STATUS_PROCESS_FAILURE received from VARY -PID(14213)

2017-10-12 14:19:16 VARY[29286]:
2166 I va_drv_updt.c 1 403
Desired state for DRIVE 1, 3, 1,13 set to STATE_OFFLINE.

2017-10-12 14:19:16 ACSSA[29286]:
1433 N sa_demux.c 1 296
drive 1, 3, 1,13: Offline.

 

'query drive 1,3,1,13' is still showing the old drive type of "LTO-4" instead of "T1D"

Changes

Replaced an LTO4 drive with a T10KD drive.

Cause

There could have been some flag or status in memory associated to the drive that is causing the config command to go into a timeout condition.
 

Solution

The workaround is to restart ACSLS.

See Bug 26964587 - ACSLS - 'config drives' and 'config acs' Error: "Timed out waiting for message"


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.