Solution Type Problem Resolution Sure Solution 2318452.1 : ACSLS - Drive Replaced But Cannot be Configured Using 'config drives' or 'config acs'
In this Document
Created from <SR 3-15922994371> Applies to:Sun StorageTek T10000B Tape Drive - Version All Versions to All Versions [Release All Releases]Sun StorageTek Auto Cartridge Sys Lib SW (ACSLS) - Version 8.2 to 8.2 [Release 8.0] Information in this document applies to any platform. SymptomsAn LTO4 drive is replaced with a T10KD drive. 2017-10-12 20:03:45 ACSCFG[36296]: 126 N cfg_drv_state.c 1 1006 cfg_drv_state:st_req_error: Timed out waiting for message 2017-10-12 20:03:45 ACSSA[0]: 1435 W sa_demux.c 1 296 Unable to handle unusual status or event. See related messages.
-- 2017-10-12 22:59:17 ACSCFG[40576]: 126 N cfg_acs_state.c Unknown 309 cfg_acs_state:st_req_error: Timed out waiting for message -
$ config drives 1,3,1 2017-10-12 20:40:30 Obtaining Configuration details, please wait Dynamic config failed with status STATUS_PROCESS_FAILURE
2017-10-12 14:15:28 VARY[29137]:
'query drive 1,3,1,13' is still showing the old drive type of "LTO-4" instead of "T1D" ChangesReplaced an LTO4 drive with a T10KD drive. CauseThere could have been some flag or status in memory associated to the drive that is causing the config command to go into a timeout condition. SolutionThe workaround is to restart ACSLS. See Bug 26964587 - ACSLS - 'config drives' and 'config acs' Error: "Timed out waiting for message" Attachments This solution has no attachment |
||||||||||||||||||
|