Solution Type  Problem Resolution Sure

Solution  2317820.1 :   SL3000 - Newly Installed SL3000 Does Not Complete Initialization, Missing 48Volts  


Related Items
  • Sun StorageTek SL3000 Modular Library System
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  


SL3000 does not complete initialization and robot does not get detected upon power up sequence

In this Document
Symptoms
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: INFORMATIONAL
Created from <SR 3-15524660951>

Applies to:

Sun StorageTek SL3000 Modular Library System - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

After the first power on the library does not complete initialization, no power (48V DC) on copper rail available.

Cause

No power (48V DC) on the copper rail, hence the robot does not get detected and the initialization sequence does not continue.
 

Solution

Replaced PUW logic card, this regained power to the robot (48V DC on copper rail).