Solution Type  Problem Resolution Sure

Solution  2316151.1 :   Oracle ZFS Storage Appliance: VMware Host Unable To See ISCSI Lun When Added To Initiator Group  


Related Items
  • Sun ZFS Storage 7420
  •  
  • Oracle ZFS Storage ZS5-2
  •  
  • Oracle ZFS Storage ZS3-2
  •  
  • Sun Storage 7110 Unified Storage System
  •  
  • Sun Storage 7210 Unified Storage System
  •  
  • Oracle ZFS Storage Appliance Racked System ZS5-4
  •  
  • Oracle ZFS Storage ZS4-4
  •  
  • Sun Storage 7410 Unified Storage System
  •  
  • Oracle ZFS Storage ZS5-4
  •  
  • Oracle ZFS Storage ZS3-4
  •  
  • Sun ZFS Storage 7120
  •  
  • Sun Storage 7310 Unified Storage System
  •  
  • Oracle ZFS Storage Appliance Racked System ZS5-2
  •  
  • Sun ZFS Storage 7320
  •  
  • Oracle ZFS Storage Appliance Racked System ZS4-4
  •  
  • Oracle ZFS Storage ZS3-BA
  •  
Related Categories
  • PLA-Support>Sun Systems>DISK>ZFS Storage>SN-DK: ZS
  •  




In this Document
Symptoms
Changes
Cause
Solution


Created from <SR 3-15879927671>

Applies to:

Oracle ZFS Storage Appliance Racked System ZS5-4 - Version All Versions and later
Oracle ZFS Storage Appliance Racked System ZS5-2 - Version All Versions and later
Oracle ZFS Storage ZS5-4 - Version All Versions and later
Oracle ZFS Storage ZS5-2 - Version All Versions and later
Oracle ZFS Storage Appliance Racked System ZS4-4 - Version All Versions and later
7000 Appliance OS (Fishworks)

Symptoms

VMware host is unable to see iSCSI LUNS if they are assigned to an initiator group, but the VMware host will see the iSCSI LUNS if they are assigned to "All initiators".

 

Changes

This was a new configuration of a VMware host mapping iSCSI LUNS from a ZFS Storage Array

 

Cause

The IQN from the VMware host was using the hostname as part of it. The hostname was all capital letters.   Example: iqn.2017-09.com.companyname:HOSTNAME

The iSCSI specification only allows lower case letters in the IQN.   Example: iqn.2017-09.com.companyname:hostname

The ZFS Appliance will only allow lower case letters to be entered into the initiator field.

 

Solution

The solution is to change the IQN name on the VMware host to use lower case letters and other valid characters.

VMware can provide instruction on how to make this change.

 