Symptoms
Changes
Cause
Solution


Created from <SR 3-15812854231>

Applies to:

StorageTek SL150 Modular Tape Library - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

Boot failed with following messages:

Kernel panic not syncing: VFS: unable to mount root is on unknown block(1,0).
Loading curr_ver/ramdisk.img.gz

Changes

 Reboot the library.

Cause

Mount failed during the boot process.

Solution

Robot assembly includes the components related with this process.

Replace the robot assembly.
 