Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2310346.1
Update Date:2018-04-02
Keywords:

Solution Type  Problem Resolution Sure

Solution  2310346.1 :   T10000D - Tape Drive Is Not Initializing - status (FSC 1301) "Device response time-out"  


Related Items
  • StorageTek T10000D Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Changes
Cause
Solution
References


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: Need Field Engineer action
Created from <SR 3-15751978141>

Applies to:

StorageTek T10000D Tape Drive - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

T10000D is not initializing in SL8500 eventlog is showing 1301 "Device response time-out".

Time : 2017-09-15T00:38:21.804
Device Address : 1.2.-2.1.3
User : root
Requester : default
Activity : internal
Request Id : 0
Level : error
Result Code : 1301
Text : "Device response time-out"
Parameters : request=<request sequence="469986"><command>controlPower</command><requestId>Internal</requestId><parms><address>1,2,-2,1,3</address><powerState>on</powerState></parms></request>

 

Changes

 

Cause

The tape drive is not initializing because problem in HBD / LOD card problem.

Solution

The problem was identified through swap with parts of other Tape Drive loaned by customer.

The T10000D was replace according KB below:

SL8500 - How to Remove and Replace the Drive Tray Power Supply Card (Doc ID 2336817.1)


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.