![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2307595.1 : T10000D - Drive Fails With an "Overtemp" Error Message, FSC A000
In this Document
Oracle Confidential PARTNER - Available to partners (SUN). Applies to:StorageTek T10000D Tape Drive - Version All Versions and laterInformation in this document applies to any platform. Drive had been replaced for same issue the day before. SymptomsDrive fails with an "overtemp" error message. The drive stops working. After a reset it will work for a while, but then goes offline again. FSC A000 indicating over temp, CauseThe drive has a separate cooling tray which could be the cause of the over temp. SolutionReplace the 7052400 [F] Fan Assembly. Applies to:StorageTek T10000D Tape Drive Attachments This solution has no attachment |
||||||||||||||||||
|