Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2306775.1
Update Date:2018-01-03
Keywords:

Solution Type  Problem Resolution Sure

Solution  2306775.1 :   SL150 - Drives Persistent Binding Is Not Working and Tape Drives Can Not be Seen by the Server  


Related Items
  • StorageTek SL150 Modular Tape Library
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: Tape Library Control Software
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-15689107741>

Applies to:

StorageTek SL150 Modular Tape Library - Version All Versions to All Versions [Release All Releases]
Linux x86-64

Symptoms

The drives can not connect to the server using persistent binding.

Cause

Library needs a reboot to allow drives to connect to the server.

Solution

SL150 rebooted.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.