Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2305179.1
Update Date:2017-09-07
Keywords:

Solution Type  Problem Resolution Sure

Solution  2305179.1 :   Cisco 4948E Power Supply Off  


Related Items
  • Exadata X5-2 Quarter Rack
  •  
Related Categories
  • PLA-Support>Sun Systems>SAND>Network>SN-SND: Sun Network Ethernet Switches
  •  




In this Document
Symptoms
Cause
Solution


Created from <SR 3-15692349865>

Applies to:

Exadata X5-2 Quarter Rack - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms

Cisco Switch had power failure on PS2.

cisco>show power
Power Fan Inline
Supply Model No Type Status Sensor Status
------ ---------------- --------- ----------- ------- -------
PS1 PWR-C49E-300AC-F AC 300W good good n.a.
PS2 PWR-C49E-300AC-F AC 300W bad/off bad/off n.a.<------------------------------------

Cause

Possible cause includes unplugged AC power cord, tripped circuit breaker or defective power supply module.
 

 

Solution

Open Oracle Service Request and  ask for Field Engineer to come on site to check that the AC power cable is seated properly and circuit breaker is not tripped.  As a last resort, the Field Engineer will replace the Power Supply Module.
 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.
 Feedback