Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2305110.1
Update Date:2018-05-17
Keywords:

Solution Type  Problem Resolution Sure

Solution  2305110.1 :   T10000 - FSC: 5534 AUDIT_FSC_UNSEATED_CARTRIDGE_LEADER_DURING_UNBUCKLE  


Related Items
  • StorageTek T10000C Tape Drive
  •  
  • Sun StorageTek T10000 Tape Drive
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: STK T-Series Drive
  •  




In this Document
Symptoms
Changes
Cause
Solution


Oracle Confidential PARTNER - Available to partners (SUN).
Reason: INFORMATIONAL
Created from <SR 3-15698420601>

Applies to:

StorageTek T10000C Tape Drive - Version All Versions to All Versions [Release All Releases]
Sun StorageTek T10000 Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Log Entry: 5, Volser: M00446
Log Time: 06/22/2017 09:00:29.142
-----------------------------------------------------------------
Rec/ Sev/MIM Len Servo COT
Event Route (dec) FSC Path Block ID Position Wrap Position
----- ----- ---- ---- ---- -------- -------- ---- --------
04-da 51-05 36 499e-0006 00000000 00000000 0000 0000f8a1

This SNO dump is a result of a preceding failure during unload of the following cartridge with FSC 5534
Log Entry: 4, Volser: M00446
Log Time: 06/22/2017 09:00:29.136
-----------------------------------------------------------------
Rec/ Sev/MIM Len Servo COT
Event Route (dec) FSC Path Block ID Position Wrap Position
--------------------------------------------------
04-a2 41-05 292 5534-0000 00000000 00000000 0000 0000f8a1

FSC: 5534 AUDIT_FSC_UNSEATED_CARTRIDGE_LEADER_DURING_UNBUCKLE

Changes

 

Cause

Unload problems on cartridge M00446.

Solution

1. Check the current status on T10K-T2 cartridge M00446 if this cartridge can be loaded and unloaded without any issues

2. Delete the dump from the drive.  This should than eventually clear the status in STA.
  In MD-VOP with CSE version only!!!
  a. The affected drive has an orange LED that indicates that a dump is present on the drive.
  b. Select the "Retrieve" pull down.
  c. Select "Delete Dumps".
 


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.