![]() | Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition | ||
|
|
![]() |
||||||||||||||||||
Solution Type Problem Resolution Sure Solution 2304917.1 : SL8500 - Audit Cannot Complete Due to Hardware Failure, Result Code : 3324 com.stortek.ats.elib.server.common.LcException: Cap Unlocked
In this Document
Created from <SR 3-15543380791> Applies to:Sun StorageTek SL8500 Modular Library System - Version All Versions and laterInformation in this document applies to any platform. Trying to run an audit with the CAP in automatic mode, the audit fails. This happens when using SLConsole and it also happens when using command proc. SymptomsAudit cannot complete due to hardware failure com.stortek.ats.elib.server.common.LcException: Cap unlocked 2017-09-05T13:28:02.141 1,0,0,0,0 root default AuditDaemon -1061301error 3324 Audit cannot complete due to hardware failure com.stortek.ats.elib.server.common.LcException: Cap unlocked startAddress=1,3,15,2,1 endAddress=1,3,15,2,13 2017-09-05T13:28:20.455 1,0,0,0,0 root default AuditDaemon -1061101error 3324 Audit cannot complete due to hardware failure com.stortek.ats.elib.server.common.LcException: Cap unlocked startAddress=1,2,15,2,1 endAddress=1,2,15,2,13 2017-09-05T13:28:29.857 1,0,0,0,0 root default AuditDaemon -1061801error 3324 Audit cannot complete due to hardware failure com.stortek.ats.elib.server.common.LcException: Cap unlocked startAddress=1,4,15,2,1 endAddress=1,4,15,2,13 CauseUnknown. SolutionChange the CAP mode to manual. References<NOTE:2267354.1> - sl8500 - FSC 3324, Audit Cannot Complete Due To Hardware Failure<NOTE:1014904.1> - How to Place a CAP into Automatic or Manual Mode in an HSC Controlled Tape Library <NOTE:1014338.1> - ACSLS - How to Set CAP to Automatic (or Manual) Mode Attachments This solution has no attachment |
||||||||||||||||||
|