Sun Microsystems, Inc.  Oracle System Handbook - ISO 7.0 May 2018 Internal/Partner Edition
   Home | Current Systems | Former STK Products | EOL Systems | Components | General Info | Search | Feedback

Asset ID: 1-72-2303302.1
Update Date:2017-12-05
Keywords:

Solution Type  Problem Resolution Sure

Solution  2303302.1 :   SL8500 - SLS0662I LMU Response Error Appearing on the HSC Log After a Library Reboot  


Related Items
  • Sun StorageTek SL8500 Modular Library System
  •  
  • Sun StorageTek Host Software Component (HSC)
  •  
Related Categories
  • PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
  •  
  • Microlearning>Text>ML-TXT-Document
  •  


SL8500 causing the HSC to produce LMU response errors

In this Document
Symptoms
Cause
Solution


Created from <SR 3-15566713101>

Applies to:

Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Sun StorageTek Host Software Component (HSC) - Version 7.3 to 7.3 [Release 7.0]
Information in this document applies to any platform.

Symptoms

HSC log messages:

SLS0662I LMU RESPONSE ERROR - 01,000,18,00
SLS0698I REQ ACS 01 SEQ 09/126 REQ B MOUNT VOL 984070 SRC 03/07:06:01 CEL TGT 00/01:10:00 DRV 314A
SLS0699I RESPONSE ACS 01 SEQ 09/126 ERR 07/08 ROBOTIC MOVE FAILED RET'D TO SRC LSM 03
SLS0120E MOUNT OF 984070 ON DRIVE 314A - LMU ERROR 65156515 ACS 01
*33 RECOVERY

Cause

HSC reported error messages:
Got the below error message after a reboot of the SL8500 library .

SLS0662I LMU RESPONSE ERROR - 01,000,18,00
SLS0698I REQ ACS 01 SEQ 09/126 REQ B MOUNT VOL 984070 SRC 03/07:06:01 CEL TGT 00/01:10:00 DRV 314A
SLS0699I RESPONSE ACS 01 SEQ 09/126 ERR 07/08 ROBOTIC MOVE FAILED RET'D TO SRC LSM 03
SLS0120E MOUNT OF 984070 ON DRIVE 314A - LMU ERROR 65156515 ACS 01
*33   RECOVERY

  VOLSER: 984070
  MEDIA: T1D000T2
  ACSID: 01
  SIZE(MB): 8000000
  MIGRATED COUNT: 0
  %AVAILABLE: 100.00
  %USABLE: 100.00
  TIMES MOUNTED: 3471
  LAST MOUNTED: 2017AUG17 03:59:08
  LAST MIGRATION: 2016DEC21 19:23:51
  LAST DRAIN/RECLAIM: 2017JAN02 10:23:22
  LAST VERIFIED: 2016JUL22 18:34:36
  MVCPOOL: DEFAULTPOOL
  SECURITY ACCESS: NO PROFILE
  STORAGE FORMAT: STANDARD
  STATUS: INITIALIZED
  LOST - FAILED TO MOUNT

Solution

HSC recycled and the LMU errors do not show now.


Attachments
This solution has no attachment
  Copyright © 2018 Oracle, Inc.  All rights reserved.