Asset ID: |
1-72-2303302.1 |
Update Date: | 2017-12-05 |
Keywords: | |
Solution Type
Problem Resolution Sure
Solution
2303302.1
:
SL8500 - SLS0662I LMU Response Error Appearing on the HSC Log After a Library Reboot
Related Items |
- Sun StorageTek SL8500 Modular Library System
- Sun StorageTek Host Software Component (HSC)
|
Related Categories |
- PLA-Support>Sun Systems>TAPE>Tape Hardware>SN-TP: SL3000-8500 Library
- Microlearning>Text>ML-TXT-Document
|
SL8500 causing the HSC to produce LMU response errors
In this Document
Created from <SR 3-15566713101>
Applies to:
Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Sun StorageTek Host Software Component (HSC) - Version 7.3 to 7.3 [Release 7.0]
Information in this document applies to any platform.
Symptoms
HSC log messages:
SLS0662I LMU RESPONSE ERROR - 01,000,18,00
SLS0698I REQ ACS 01 SEQ 09/126 REQ B MOUNT VOL 984070 SRC 03/07:06:01 CEL TGT 00/01:10:00 DRV 314A
SLS0699I RESPONSE ACS 01 SEQ 09/126 ERR 07/08 ROBOTIC MOVE FAILED RET'D TO SRC LSM 03
SLS0120E MOUNT OF 984070 ON DRIVE 314A - LMU ERROR 65156515 ACS 01
*33 RECOVERY
Cause
HSC reported error messages:
Got the below error message after a reboot of the SL8500 library .
SLS0662I LMU RESPONSE ERROR - 01,000,18,00
SLS0698I REQ ACS 01 SEQ 09/126 REQ B MOUNT VOL 984070 SRC 03/07:06:01 CEL TGT 00/01:10:00 DRV 314A
SLS0699I RESPONSE ACS 01 SEQ 09/126 ERR 07/08 ROBOTIC MOVE FAILED RET'D TO SRC LSM 03
SLS0120E MOUNT OF 984070 ON DRIVE 314A - LMU ERROR 65156515 ACS 01
*33 RECOVERY
VOLSER: 984070
MEDIA: T1D000T2
ACSID: 01
SIZE(MB): 8000000
MIGRATED COUNT: 0
%AVAILABLE: 100.00
%USABLE: 100.00
TIMES MOUNTED: 3471
LAST MOUNTED: 2017AUG17 03:59:08
LAST MIGRATION: 2016DEC21 19:23:51
LAST DRAIN/RECLAIM: 2017JAN02 10:23:22
LAST VERIFIED: 2016JUL22 18:34:36
MVCPOOL: DEFAULTPOOL
SECURITY ACCESS: NO PROFILE
STORAGE FORMAT: STANDARD
STATUS: INITIALIZED
LOST - FAILED TO MOUNT
Solution
HSC recycled and the LMU errors do not show now.
Attachments
This solution has no attachment